Download Print this page

Panasonic SR-DF101 Service Manual page 21

Electronic warm jar

Advertisement

8 Inspection method of components on control board
LED5
LED
Detection
Qualifi ed Defective
method
If LED5 lights up
Yes
No
when it is short-
circuited between
TP [G] and [L5]?
SW4
Tact switch
Detection
Qualifi ed Defective
method
H o l d d o w n
Yes
No
S W 4
a n d
m e a s u r e i f
the resistance
b e t w e e n T P
[VD] and [S4]
is 0 Ω?
LED4
LED
Detection
Qualifi ed Defective
method
If LED4 lights
Yes
No
up when it is
short-circuited
between TP
[G] and [L4]?
SW2
Tact switch
Detection
Qualifi ed Defective
method
H o l d d o w n
Yes
No
S W 2 a n d
m e a s u r e i f
the resistance
between TP
[VD] and [S2]
is 0 Ω?
RL
Relay
Inspection method
Qualifi ed Defective
Connect TP[G]-[RL1],
Yes
and check if the power
c o n s u m p t i o n i s t h e
rated cooking power.
Unplug the power and
Yes
check if the resistance
between TP [A1] and
[RL5] is ∞ Ω?
N o t e 1 : D i s c o n n e c t
t h e c o n n e c t o r C N 3
before measuring the
resistance.
Note 2: Connect one
end of TP [A1] to the
positive terminal.
SW5
Tact switch
Detection method Qualifi ed Defective
H o l d d o w n S W 5
Yes
and measure if the
resistance between
TP [VD] and [S5] is
0 Ω?
No
No
SW6
Tact switch
Detection method
Qualifi ed
No
H o l d d o w n S W 6
Yes
and measure if the
resistance between
TP [VD] and [S6] is
0 Ω?
19
X1
Crystal
Detection
Qualifi ed Defective
Defective
method
No
Output 8 MHZ
Yes
between TP
[G] and [X1]?
SW3
Tact switch
Detection
Qualifi ed Defective
method
H o l d d o w n
Yes
S W 3
a n d
m e a s u r e i f
the resistance
b e t w e e n T P
[VD] and [S3]
is 0 Ω?
LED3
LED
Detection
Qualifi ed Defective
method
If LED3 lights
Yes
up when it is
short-circuited
b e t w e e n T P
[G] and [L3]?
SW1
Tact switch
Detection
Qualifi ed Defective
method
H o l d d o w n
Yes
S W 1
a n d
m e a s u r e i f
the resistance
b e t w e e n T P
[VD] and [S1]
is 0 Ω?
LED1
LED
Detection
Qualifi ed Defective
method
If LED1 lights
Yes
up when it is
short-circuited
between TP [G]
and [L1]?
LED2
LED
Detection
Qualifi ed Defective
method
If LED2 lights
Yes
up when it is
short-circuited
between TP [G]
and [L2]?
No
No
No
No
No
No

Advertisement

loading