Click the button to test the relay / output connection.
7.7

Alarm Task Editor

Editing scripts on this page overwrites all settings and entries on the other alarm pages. This
procedure cannot be reversed.
To edit this page, you should have programming knowledge and be familiar with the
information in the Alarm Task Script Language document and the English language.
As an alternative to the alarm settings on the various alarm pages, enter the desired alarm
functions in script form here. This will overwrite all settings and entries on the other alarm
pages.
1.
2.
3.
7.8

Alarm Rules

An alarm rule can define which input(s) activate which output(s). Basically, an alarm rule
allows you to customize the camera to respond automatically to different alarm inputs.
To configure an alarm rule, specify one input from a physical connection, from a motion
detection trigger, or from a connection to the camera's LIVE page. The physical input
connection can be activated by dry contact devices such as pressure pads, door contacts, and
similar devices.
Next, specify up to two (2) rule outputs, or the camera's response to the input. Outputs
include a physical alarm output, an AUX command, or a preposition scene.
This alarm alerts users if anyone tries to open the housing of the device.
(Refer to the "Operating the camera with AUX commands" section of the manual for a list of
all AUX commands for your camera.)
Click the checkbox Enabled to activate the alarm.
Click Set to save. The camera's system activates the alarm rules.
Bosch Security Systems
Click Examples under the Alarm Task Editor field to see some script examples. A new
window opens.
Enter new scripts in the Alarm Task Editor field or change existing scripts in line with your
requirements.
When finished, click Set to transmit the scripts to the device. If the transfer was
successful, the message Script successfully parsed. is displayed over the text field. If it
was not successful, an error message is displayed with further information.