5. TROUBLESHOOTING GUIDE
SYMPTOM
Pump does not reach required
pressure
Pressure drops during use
Pump noisy
Presence of water in oil
Oil leaks
Motor does not start when
switched on
Motor hums but does not start
when switched on
Water dripping from pump
The motor stops
Declaration of Conformity We, the sole importer into the UK, declare that the products listed below are in conformity with the following
standards and directives.
Pressure Washers PC2275 & PC2285
73/23/EEC Low Voltage Directive
89/336/EEC EMC Directive
98/37/EC Machinery Directive
93/68/EEC CE Marking Directive
NOTE:
It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No responsibility is accepted for incorrect use of this equipment
WARRANTY: Guarantee is 12 months from purchase, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue call us on 01284 757525 and leave your full name and address, including postcode.
01284 757500
REASONS
Nozzle incorrect or worn
Air being sucked into the system
Valves dirty worn or stuck
Dirty filter
Regulator valve seat is worn
Worn piston packing
Unloader valve packing worn
Low water supply pressure
Air in pump
Valves dirty or worn
Nozzle clogged or worn
Unloader valve packing worn
Worn piston packing
Dirty filter
Water temperature too high
Pump sucking air
Valves dirty or worn
Worn bearings
Water temperature too high
Dirty filter
Water supply has been turned off
High humidity in air
Piston packing and oil seal worn
Oil seals worn
Plug is not connected
Unsuitable mains voltage
Pump is stuck
Pump is frozen
Piston packings worn
Piston O-rings worn
Tripped thermal cut-out due to
overheating
The construction files for these products are held by the Manufacturer
and may be inspected on request by contacting Jack Sealey Ltd.
Signed by Mark Sweetman
For Jack Sealey Ltd. Sole importer into the UK of Sealey Power
Sole UK Distributor,
Sealey Group,
Bury St. Edmunds, Suffolk.
01284 703534
REMEDY
Replace the nozzle.
Check that hoses and fittings are air tight.
Clean or replace valve.
Clean or replace
Replace the valve seat.
Check and replace
Check and replace
Open the water supply tap fully.
Switch off the washer and operate the gun until a steady
flow of water is obtained. Then switch washer back on.
Clean or replace valve.
Clean with tool provided or replace the nozzle.
Check and replace.
Check and replace.
Clean or replace
Reduce temperature.
Check that hoses and fittings are air tight.
Clean or replace valve.
Check and replace if necessary.
Reduce temperature.
Clean or replace.
Ensure water tap is fully on.
Increase frequency of servicing
Check and replace.
Check and replace.
Check plug connections and that mains power
supply is present.
Check for adequate power supply and cable condition.
Check by turning motor manually with allen key in motor
shaft. If jammed return to your Sealey dealer.
Leave unit to thaw naturally. The pressure washer should be
stored away from the threat of freezing. Extensive pump
damage could otherwise occur.
Check and replace
Check and replace
Check that the mains voltage matches the specifications
Switch off the motor and allow to cool for 5 minutes.