Flush-fit installation

 Create the worktop cut-out. Remem-
ber to maintain the minimum safety
distances (see "Installation – Safety
distances").
 Cut the top of the drilling template to
the thickness of your worktop. Place
it on the cabinet rear wall with side 1
facing up. Use the drilling template to
create a cut-out for the air duct or the
Plug&Play adapter.
If you do not have a drilling template,
see "Installation – Rear wall cut-out –
without drilling template".
 Solid wood, tiled and glass worktops:
Fix a wooden frame 5,5 mm below
the top edge of the worktop (see "In-
stallation dimensions – flush-fit").
 Stick the sealing strip supplied under
the edge of the hob. Do not apply the
sealing strip under tension.
The Plug&Play adapter may break
off.
When placing the hob on the work-
top, make sure that it is not placed
on top of the Plug&Play adapter.
 Feed the mains connection cable for
the hob down through the worktop
cut-out.
 Plug&Play mode: remove the protect-
ive foil from the adhesive tape at the
end of the Plug&Play adapter.
 Centre the hob in the cut-out.
The gap between the ceramic glass
surface and the worktop must be at
least 2 mm wide. This is required so
that the hob can be sealed.
 Plug&Play mode: align the Plug&Play
adapter with the predrilled hole. Press
the adapter onto the rear wall until it
sticks in place.
 Connect the hob to the power supply.
 Check that the hob works.
 Seal the gap between the hob and
worktop with a silicone sealant that is
heat-resistant to at least 160 °C.
Damage from unsuitable sealant.
Unsuitable sealant can damage nat-
ural stone.
For natural stone worktops and nat-
ural stone tiles, only use silicone
sealant that is specially formulated
for natural stone. Follow the manu-
facturer's instructions.
Installation
99