Keysight Infiniium 90000A Series User Manual
Keysight Infiniium 90000A Series User Manual

Keysight Infiniium 90000A Series User Manual

Hide thumbs Also See for Infiniium 90000A Series:

Advertisement

Keysight Infiniium
90000A Series Oscilloscopes
User's Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Infiniium 90000A Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Keysight Infiniium 90000A Series

  • Page 1 Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 2 Technology Licenses The hardware and/or software described in this document are furnished under a license and may be used or copied only in accor- dance with the terms of such license. Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 3: Infiniium 90000A Series Oscilloscopes-At A Glance

    The Infiniium oscilloscopes combine unprecedented ease-of use with high-performance digitizing oscilloscope functionality to simplify your design and analysis measurement tasks • Traditional oscilloscope front-panel interface provides direct access to the controls needed for most troubleshooting tasks Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 4 • Color-coded knobs make it easy to find the controls that affect each waveform Marker and quick measurements help measure waveform parameters • Waveform markers 1 and 2 to check voltage or -time at any point on the Δ displayed waveform Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 5: In This Guide

    • For information on testing and servicing the oscilloscope, see the Service Guide found in the Infiniium oscilloscope application’s online help. • For technical assistance, contact your local Keysight Technologies representative at http://www.keysight.com/find/contactus. Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 6 Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 7: Table Of Contents

    Contents Infiniium 90000A Series Oscilloscopes—At a Glance / 3 In This Guide / 5 1 Setting Up the Oscilloscope / 9 Safety / 10 Safety Compliance / 10 Acoustic Statement / 10 General Safety Notices / 10 Symbols / 12...
  • Page 8 Saving and Printing Data / 46 Forcing a Default Setup / 47 3 Online Help and Other Information / 49 Accessing the Online Help / 49 Navigating the Online Help / 51 Using the Demo Wizard / 52 Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 9: Setting Up The Oscilloscope

    Infiniium 90000A Series Oscilloscopes User’s Guide 1 Setting Up the Oscilloscope Safety / 10 Symbols / 12 Inspecting Package Contents / 13 Specifications and Characteristics / 14 Declaration of Conformity / 14 Positioning for Proper Airflow / 15 Connecting Accessories and Cables / 17...
  • Page 10: Safety

    If this product is not used as specified, the protection provided by the equipment WARNING could be impaired. This product must be used in a normal condition (in which all means for protection are intact) only. Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 11 This product is designed for use in Installation Category II and Pollution Degree 2. CAUTION The Rayovac BR2032 lithium battery is to be replaced by Keysight service personnel only. Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 12: Symbols

    The symbol on all primary and secondary packaging indicates compliance to China standard GB 18455-2001. To return unwanted products, contact your local Keysight office. The CSA mark is a registered trademark of the CSA International. The CE mark is a registered trademark of the European Community.
  • Page 13: Inspecting Package Contents

    • If the shipping container is damaged, or the cushioning materials show signs of stress, notify the carrier and your Keysight Technologies Sales Office. Keep the shipping materials for the carrier’s inspection. The Keysight Technologies Sales Office will arrange for repair or replacement at Keysight’s option without waiting for claim settlement.
  • Page 14: Specifications And Characteristics

    Example: Sheltered outdoor environment. The Infiniium 90000A Series oscilloscopes are heavy and awkward for a single individual to N OTE move. It is recommended that two people use the side handles to lift and carry the oscilloscope.
  • Page 15: Positioning For Proper Airflow

    Position the oscilloscope where it will have sufficient clearance for airflow around the back and sides. If you install the oscilloscope into an N5470A rack, refer to the Keysight N5470A 90000, 90000 X, and V-Series Oscilloscope Rack Mount Kit Installation Guide at www.keysight.com/find/90000a-manual.
  • Page 16: Location

    (The front panel switch is only a standby switch and is not a LINE switch.) Alternatively, an externally installed switch or circuit breaker (which is readily identifiable and is easily reached by the operator) may be used as a disconnecting device. Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 17: Connecting Accessories And Cables

    If you do not know how to set up a network in the Windows 7 operating system, see your network administrator or use the Windows 7 operating system’s online help. audio connectors LAN connector USB connector GPIB connector PS2 ports serial port parallel port USB host ports Figure 2 Back panel Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 18: Connecting Power

    10% of the nominal supply voltage. Properly Ground the Oscilloscope WARNING To avoid electric shock, be sure the oscilloscope is properly grounded. Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 19 Setting Up the Oscilloscope Figure 3 Power cord connection Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 20: Connecting Oscilloscope Probes

    Push it straight on until it latches into place. Figure 4 Attaching a probe connector Connect the probe head to the circuit of interest using the browser or other probing accessories. Figure 5 Probe browser Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 21 Keysight oscilloscope probes documentation in the Probe Resource Center (www.keysight.com/find/prc). The Keysight Infiniium 90000A Series oscilloscopes are not rated for Measurement Category II, III, or IV. Ensure that the rated voltage of any probing accessory is not exceeded by the circuit CAUTION to be measured.
  • Page 22: Connecting Sma Cables

    Setting Up the Oscilloscope Connecting SMA Cables You can connect an SMA cable to the Infiniium 90000A Series oscilloscopes (except for the DSO90254A model) by using the 54855-67604 SMA-to-precision BNC adapter. Attach the two SMA-to-precision BNC adapters to the ends of an SMA cable.
  • Page 23: Tilting The Oscilloscope For Easier Viewing

    Setting Up the Oscilloscope Tilting the Oscilloscope for Easier Viewing To angle the oscilloscope upward, lift the front of the oscilloscope and pull out the two wire feet. Figure 8 Latching the front feet Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 24: Turning On The Oscilloscope

    You can connect and disconnect probes and BNC cables while the oscilloscope is turned on. This oscilloscope does not exceed 80 dBa sound pressure level, which is considered to be below the OSHA permissible exposure level. Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 25: Verifying Basic Oscilloscope Operation

    Move the mouse around the mouse surface and verify that the on-screen pointer follows the mouse movement. Touch the pointer of the touch screen stylus to the surface of the screen and move it around while verifying that the pointer follows the movement. Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 26: Installing Application Programs On Infiniium

    8 GB of RAM or less may be installed on your Infiniium oscilloscope. Exit the oscilloscope application before installing any software. N OTE Installing an application that does not meet these requirements may break the CAUTION oscilloscope application and require a hard drive recovery. Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 27: Changing Windows Operating System Settings

    • Do not use the Administrative Tools to enable or disable Internet Information Services. Use the Infiniium SCPI Server dialog box (Utilities > Remote...) to enable or disable the Web Server. • Do not delete or modify the Infiniium Administrator user account. Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 28: Turning Off The Oscilloscope

    Allow all residual alcohol moisture to evaporate, and the fumes to dissipate prior to powering up the oscilloscope. Dispose of the cleaning materials in a responsible manner. Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 29: Using The Oscilloscope

    Saving and Printing Data / 46 Forcing a Default Setup / 47 This chapter describes how to use the Infiniium 90000A Series oscilloscope’s front-panel controls and user interface. • The familiar front-panel oscilloscope interface with knobs and keys is optimized for common tasks and basic measurements.
  • Page 30: Inputs And Outputs

    Using the Oscilloscope Inputs and Outputs On the Infiniium 90000A Series oscilloscopes, the Aux Trig input, Aux Out output, and probe compensation terminal are located on the front of the oscilloscope. The Trig Out output and 10 MHz Reference input and output are located on the back of the oscilloscope.
  • Page 31: Front Panel Controls (Keys And Knobs) Overview

    Using the Oscilloscope Front Panel Controls (Keys and Knobs) Overview The Infiniium 90000A Series oscilloscope front panel gives you direct access to the functions needed to perform the most common measurements, using a traditional oscilloscope interface. Knobs and keys let you directly set vertical and horizontal parameters.
  • Page 32: User Interface Overview

    Set vertical scale bandwidth Figure 12 Infiniium oscilloscope top of display The selected grid mode in the upper right corner determines whether you draw a selection box or manipulate waveforms when you touch the screen. Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 33 The symbol represents the ground reference point for each waveform; it moves when you change the vertical offset. You can also drag this symbol up and down to change the vertical offset for that waveform. Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 34: Menu Overview

    Take a few minutes to look through the menus to get an overview of the many features and capabilities of your Infiniium oscilloscope. The sub-menu selections will vary slightly, depending on which licenses are installed. Figure 15 Menu bar Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 35: Using The Setup And Display Controls

    [Save Screen] key or choose File > Save > Screen Image..• The first time you save a screen image you will be prompted to enter a location for the saved file. Subsequent saves automatically place the file in that location. Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 36 Clearing the waveform display also resets averaging, infinite persistence, color grade persistence, histograms, measurement statistics, and the mask testing database. Adjusting waveform brightness Turn the Intensity knob to set the waveforms to your desired brightness. Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 37: Starting And Stopping Waveform Acquisitions

    • You can also click the Run, Stop, and Single commands from the Control menu. • To set up how you want the signals to be sampled, such as sampling rate and mode, click Setup > Acquisition..Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 38: Adjusting The Horizontal Time Scale And Trigger Position

    Stretching the waveform means fewer seconds are displayed per division. Shrinking it means more seconds are displayed per division. • Push and turn the horizontal scale knob to change the scaling in finer (Vernier) increments. Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 39 • The Timebase Reference control is a slider from 0 to 100% of the screen. The center of the screen is at 50%. The slider correlates to the solid orange triangle at the bottom of the display area, showing you where the horizontal offset is on the screen. Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 40: Adjusting The Vertical Settings

    If you are not using a particular analog channel, you can turn it off to simplify the waveform display and increase the display update rate. Functions continue to run on a channel source that is turned off. Data acquisition continues for a channel if a function requires it. Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 41 You can also specify the characteristics of a probe, or perform a probe calibration. For Keysight Technologies probes that are compatible with AutoProbe I interfaces, the oscilloscope will automatically set these characteristics (except for skew) after identifying the probe when it is connected to the channel input.
  • Page 42: Setting Up Triggers

    You can also drag the trigger reference indicator at the left side of the display, or drag the trigger line itself, which appears when you click or touch the grid. Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 43: Using Markers And Making A Measurement

    Click and drag a measurement icon to the waveform event you want to measure, or click a measurement icon and specify which source you want to measure in the dialog box that appears. Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 44 • To measure parameters for another waveform, press the [Multi Purpose] key until that waveform is the one shown in the measurement readout. Continuing to press the [Multi Purpose] key cycles through each of the waveforms available. Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 45 • Drag a marker to quickly move it to the desired waveform event. You can use the Marker Position knobs for fine adjustment, or click Measure > Markers... or the Markers button and set the marker position precisely. Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 46: Saving And Printing Data

    • Click File > Print... to send waveform and setup data to a specified printer. • Click File > Copy Screen Image to easily copy and paste a screen image into a document. • You can customize the [Multi Purpose] key to perform a QuickPrint. Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 47: Forcing A Default Setup

    If the options are not installed, install them using the license keys provided on the oscilloscope option license certificates you received, or refer to the back of the oscilloscope. Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 48 Using the Oscilloscope Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 49: Online Help And Other Information

    Infiniium 90000A Series Oscilloscopes User’s Guide 3 Online Help and Other Information Accessing the Online Help / 49 Navigating the Online Help / 51 Using the Demo Wizard / 52 Most of the information about using the Infiniium oscilloscope effectively is included in the online help.
  • Page 50 Figure 24 Online Help home page For information about items in a dialog box, click the Help button in that dialog box. Displays the Help topic for this dialog box Figure 25 Help button for dialog box Help Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 51: Navigating The Online Help

    Use the Search tab to type in a keyword and if that word exists in the online help, a list of topics containing the keyword appears. Use the Favorites tab to add preferred help topics to a list for easy reference. Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 52: Using The Demo Wizard

    Wizard..You can then select a specific demo, such as a particular protocol or a UI demo showing bookmarks. For example, the following screen display shows the initial demo page for the FFT function. To experiment with the demo, click Load Demo..Figure 26 FFT demo Keysight Infiniium 90000A Series Oscilloscopes User’s Guide...
  • Page 54 This information is subject to change without notice. © Keysight Technologies 2007, 2008, 2015, 2017 Fourth edition, February 2017 *54913-97029* 54913-97029 www.keysight.com...

Table of Contents