Download Print this page

NEC VT695 Control Commands page 32

Control commands
Hide thumbs Also See for VT695:

Advertisement

DATA03
Projector status
00H : Idling
01H : Power On
DATA04
Cooling processing
00H : No execution(Normal condition)
01H : During execution
DATA05
Power On/Off processing
00H : No execution(Normal condition)
01H : During execution
DATA06
Status of operation
00H : Idling
04H : Power On
05H : Cooling
06H : Idling(Error occurrence)
Other than above : (nondisclosure)
Internal use of code during a state transition period
DATA07
PC Card insertion
00H : Not inserted
01H : Inserted
DATA08
USB Mouse connection
00H : Not connected
01H : Connected
DATA09 .. 16 Reserved
Response: At the time of a failure
A0H 85H 01H xxH 02H DATA01 DATA02 CKS
(*1) (*2)
078-3. INPUT STATUS REQUEST
**********************************************************************
Function:
This command acquires the status of input signal of the projector.
Command:
00H 85H 00H 00H 01H 02H 88H
Response: At the time of a success
20H 85H 01H xxH 10H DATA01 .. DATA16 CKS
(*1) (*2)
Data Portion Contents
-------------------------------------------------------------------
DATA01
Selecting signal processing
00H : No execution(Normal condition)
01H : During execution
DATA02
Signal number( Entry list number - 1 )
0 .. 199
(*4)
(*3)
(*3)