Loading Code Libraries; Search Mode; Checking Code-Library Number; Sleep Mode - NAD VISO TWO Owner's Manual

Nad viso two: user guide
Hide thumbs Also See for VISO TWO:
Table of Contents

Advertisement

LOADING CODE LIBRARIES
The HTR 6 can store a different library of default NAD codes for each of its
Device Selector "pages. " If the original default library does not control your
NAD CD player, DVD player, or other component, follow the procedure
below to change the code-library.
Begin by ensuring that the component you wish the HTR 6 to control is
plugged in and powered-up ("on, " not merely in standby). To enter the
HTR 6's Library Mode, simultaneously press-and-hold for 3 seconds both the
desired Device Selector key and the [PROGRAM] key, until the Learn LED
turns green.
While keeping the HTR 6 pointed toward the component, enter the first
appropriate three-digit code-library number from the table below. Press
[OFF]. If the component turns off, press [ENTER] to accept that code-library
number and exit the Library Mode. If the component does not turn off,
enter the next three-digit code-library number from the table.
When you enter the correct number the component will turn off; press
[ENTER] to accept that code library number and exit the Library Mode.
NAD PRODUCT
LIBRARY CODE
DESCRIPTION
Receiver/Processor
100
(Discrete ON/OFF)
Receiver/Processor
101
(Toggle ON/OFF)
102
S170
103
L75
104
Second Zone Commands
105
L70
106
L76
107
118
108
L53
109
L73
Stereo Receiver/
110
Amplifier
111
Stereo Second Zone
112
Txx5 Series
200
CD Player
201
CD Player (old)
202
5170, 5240, 5340
203
5325
204
5060
205
M5
300
Tuner
SEARCH MODE
If none of the codes from the table, when entered, turns on the
component, and if you are quite sure you have followed the above
procedure completely and carefully, you may want to try the "search"
method as follows:
Enter Library Mode by simultaneously pressing-and-holding for 3 seconds
both the desired Device Selector key and the [PROGRAM] button until the
Learn LED turns green. Now press-and-hold the HTR 6's [
remote will step through all the available codes at a rate of approximately
1 per second.
NAD PRODUCT
LIBRARY CODE
DESCRIPTION
301
L75, L76 Tuner
302
L70 Tuner
303
L53 Tuner
304
L73 Tuner
305
C425
306
C445
307
Txx5 Series Tuner
400
Tape Deck B
401
TAPE Deck A
500
TV 280
501
MR13
502
MR20
503
PMR45
600
T535, T562, T585, M55
601
T550, L55
T512, T531, T532, T571,
602
T572
603
L70, L73 DVD
604
L56
T513, T514, T515, T524,
605
T533, T534
606
L53 DVD
]) key; the
uSing the htr 6 remote control
When the component turns off, immediately release the cursor key; press
[ENTER] to accept that code-library and exit the Library Mode. Try a few
commands; should you prove to have stepped past the needed code-
library, re-enter the Library Mode and use the cursor key to step back to it.
NOTE
It is possible that search mode will find code-libraries that operate, at
least partially, some other brand (non-NAD) components. You may
certainly exploit such capabilities as you find them. However, since we
can only ensure the completeness or accuracy of NAD code-libraries, we
cannot support the HTR 6's operation with other-brand components.
CHECKING CODE-LIBRARY NUMBER
You can check the current code-library on any Device Selector key as
follows. Enter Library Mode by simultaneously pressing-and-holding for
3 seconds both the desired component's Device Selector key and the
[PROGRAM] key until the Learn LED turns green. Press the [DISP] key; the
HTR 6 indicates the current code-library by flashing its [CUSTOM], [VCR],
and [MACRO] keys.
For example, to indicate code-library #501, the HTR 6 will flash [CUSTOM] 5
times, pause, and then flash [MACRO] once. You might wish to make a note
of your components' code-library numbers.
Summary of the HTR 6 Modes
Mode
Learn/Copy/Punch Through
Delete Mode
Macro Record
Library Mode
Back Light Timeout
Factory Reset
SLEEP MODE
The Sleep Mode timer will switch the VISO TWO to Standby mode
automatically after a preset number of minutes. Pressing the HTR 6's SLEEP
button once will display the setting of the sleep time increment. Pressing
the HTR 6's SLEEP button a second time within a 3-second period will
change the sleep time increment in 30-minute intervals, after which time
the VISO TWO will automatically switch into Standby mode.
To adjust the sleep delay, press the HTR 6's SLEEP button twice; first to
display the sleep time increment, and a second time to change the
sleep time increment. The sleep time increment and a "SLEEP" icon will
continuously display on the VISO TWO's front panel Vacuum Fluorescent
Display (VFD). Each consecutive press increases the sleep time in 30-minute
increments from 30 to 90 minutes. To cancel the sleep mode, continue
pressing the HTR 6's SLEEP button until "Sleep Off" displays on the VFD.
Switching the VISO TWO to standby from either the HTR 6's OFF or the
VISO TWO's POWER button will also cancel the sleep mode
NOTE
In order to use SLEEP button, make sure that HTR 6's DEVICE SELECTOR
page is set to "AMP".
OPERATION
Keys To Press (for 3 seconds)
Device Key + [ ] Key
Device Key + RTN Key
Macro Key + Function Key
Device Key + Program Key
DISP Key + Digit Key
See "Factory Reset" above
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents