Siemens SIMOTICS S-1FK2 Service Manual page 40

Encoder replacement
Hide thumbs Also See for SIMOTICS S-1FK2:
Table of Contents

Advertisement

Description
2.4 Encoder replacement variants
4. Enter parameter 4690 into the list.
Enter component number
example it is "7".
5. Switch off the CU and switch on again (POWER OFF -> POWER ON).
Start the write operation: Enter p4691 = 2
Setting p4691 = 2 starts the transfer of the electronic rating plate from the storage medium of
the converter into the encoder of the motor with the component number from p4690.
38
Parameter
"Add" to transfer into the list
Parameter
Number of the component without motor data from the alarm message
from the alarm message into the "value" column, in this
Encoder replacement for SIMOTICS S-1FK2 and S-1FT2
Service Manual, 07/2022, A5E52211160B AA