ELECTRICAL AND CONTROL SETTINGS
Monobloc system - R410A YUTAKI M
Power supply
Model
RASM-4VNE
RASM-5VNE
1~ 230V 50Hz
RASM-6VNE
RASM-4NE
RASM-5NE
3N~ 400V 50Hz
RASM-6NE
?
N O T E
The data corresponding to DHW tank heater is calculated in combination with the domestic hot water tank accessory "DHWT-(200/300)S-3.0H2E".
Monobloc system - R32 YUTAKI M
Model
Power supply
RASM-2VRE
1~ 230V 50Hz
RASM-3VRE
?
N O T E
The data corresponding to DHW tank heater is calculated in combination with the domestic hot water tank accessory "DHWT-(200/300)S-3.0H2E".
79
PMML0575 rev.2 - 03/2022
Operation mode
Without DHW tank heater
With DHW tank heater
Without DHW tank heater
With DHW tank heater
Without DHW tank heater
With DHW tank heater
Without DHW tank heater
With DHW tank heater
Without DHW tank heater
With DHW tank heater
Without DHW tank heater
With DHW tank heater
Operation mode
Without DHW tank heater
With DHW tank heater
Without DHW tank heater
With DHW tank heater
Power supply
Max.
cables
current
(A)
EN60335-1
31
2 x 6.0 mm² + GND
43
2 x 10.0 mm² + GND
31
2 x 6.0 mm² + GND
43
2 x 10.0 mm² + GND
31
2 x 6.0 mm² + GND
43
2 x 10.0 mm² + GND
14
4 x 4.0 mm² + GND
27
4 x 6.0 mm² + GND
14
4 x 4.0 mm² + GND
27
4 x 6.0 mm² + GND
16
4 x 6.0 mm² + GND
29
4 x 10.0 mm² + GND
Power supply
Max.
cables
current
(A)
EN60335-1
11
2 x 2.5 mm² + GND
23
2 x 6.0 mm² + GND
16.0
2 x 4.0 mm² + GND
29
2 x 6.0 mm² + GND
Transmitting
Actuator
cables
cables
EN60335-1
EN60335-1
2 x 0.75 mm
2
2 x 0.75 mm
2
(Shielded
+ GND
cable)
Transmitting
Actuator
cables
cables
EN60335-1
EN60335-1
2 x 0.75 mm
2
2 x 0.75 mm
+
2
(Shielded
GND
cable)