Marantz PM7200 User Manual

Marantz PM7200 User Manual

Marantz pm7200 audio-componentsystem: user manual
Hide thumbs Also See for PM7200:

Advertisement

Model PM7200 User Guide

Integrated Amplifier

PM7200U(表1,表2,表4,他)
Adobe PageMaker 6.5J/PPC
Page 4
03.12.17, 11:19 AM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PM7200 and is the answer not in the manual?

Questions and answers

Summary of Contents for Marantz PM7200

  • Page 1: Integrated Amplifier

    Model PM7200 User Guide Integrated Amplifier PM7200U(表1,表2,表4,他) Adobe PageMaker 6.5J/PPC Page 4 03.12.17, 11:19 AM...
  • Page 2 CONTENTS Engligh ... page 1 Figures ... page 35 PM7200U(表1,表2,表4,他) Page 6 03.12.17, 11:19 AM Adobe PageMaker 6.5J/PPC...
  • Page 3 CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, REFER SERVICING TO QUALIFIED SERVICE PERSONNEL WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. CAUTION: TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF PLUG TO WIDE SLOT, FULLY INSERT.
  • Page 4: Important Safety Instructions

    IMPORTANT SAFETY This product was designed and manufactured to meet strict quality and safety standards. There are, however, some installation and operation precautions which you should be particularly aware of. Read Instructions – All the safety and operating instructions should be read before the product is operated. Retain Instructions –...
  • Page 5 Servicing – Do not attempt to service this product yourself as opening or removing covers may expose you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel. Damage Requiring Service – Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions: When the power-supply cord or plug is damaged.
  • Page 6 — Should foreign matter or water get into the interior of the ampli- fier, immediately turn it off and contact your original dealer or Marantz service provider. — Never pull on the mains lead when unplugging the amplifier. Grasp the plug itself.
  • Page 7: Controls, Connectors And Indicators

    CONTROLS, CONNECTORS, AND INDICATORS (Figure 2) REMOTE CONTROL BUS TERMINALS (REMOTE CONT. BUS) These terminals can used to connect other audio equipment that is equipped with a remote control bus terminal. Connection requires a special cable. The bus OUT terminal sends signal to the connected equipment, while the bus IN terminals receive signals.
  • Page 8: Operation

    This indicator is lit while the amplifier is in the Standby Mode. Press- ing the remote control unit’s POWER buttons switches the amplifier between standby and power on. PM7200U(ENG) Page 3 OPERATION INTEGRATED AMPLIFIER PM7200 INPUT SELECTOR TAPE PHONO TUNER AUX1...
  • Page 9 TAPE DECK, CD-R/MD OPERATION INTEGRATED AMPLIFIER PM7200 INPUT SELECTOR TAPE PHONO TUNER AUX1 AUX2 CD-R/MD TAPE MUTE CD-R/MD REC SELECTOR BASS TREBLE POWER ON/OFF PHONES STANDBY SPEAKERS SOURCE TAPE CD-R CD-R TAPE COPY Perform the applicable operation on the connected tape deck.
  • Page 10 REMOTE CONTROL UNIT RC 8000PM The RC8000PM remote control unit can be used to control any Marantz AV equipment that has a remote sensor, as well as other Marantz equipment connected to the main equipment’s remote control bus. The buttons of the remote control unit are arranged on the control panel according to functional groups as shown in the illustration below.
  • Page 11 CD-R BUTTON The following are the functions assigned to control buttons after the CD-R amplifier source button is pressed. BUTTON NAME FUNCTION Play Fast-forward Fast-reverse None Stop Pause OPEN/CLOSE Open/Close Next track – Previous track A, F/P None B, –/–– None MODE Auto Music Scan (AMS)
  • Page 12: Using The Remote Control Unit

    (2) Load two batteries, making sure their positive (+) and negative (–) ends are facing correctly. Two AA-size (R6) (UM-3) batteries (3) Slide the battery compartment cover back into place and press until it clicks shut. 03.12.17, 11:18 AM Adobe PageMaker 6.5J/PPC Amplifier (PM7200)
  • Page 13: Care And Maintenance

    CARE AND MAINTENANCE This section describes care and maintenance that you must per- form in order to make sure your Marantz amplifier performs at the level for which it is designed. Be sure to unplug the amplifier from the mains supply before any care and maintenance.
  • Page 14 MODEL PM7200 TECHNICAL SPECIFICATIONS Power output (class AB operation) RMS 8 ohms (20 Hz-20 kHz) ... 95 W DIN 8 ohms ... 105 W THD at 8 ohms RMS rated output ... 0.03% Damping factor ... 150 Power output (classA operation) RMS 8 ohms (20 Hz-20 kHz) ...
  • Page 15 PM7200(SPEC, ILLUST) Page 34 03.12.17, 11:20 AM Adobe PageMaker 6.5J/PPC...
  • Page 16 Tuner Output CD player SYSTEM 2 SYSTEM 1 PM7200(SPEC, ILLUST) Page 35 Processor Output Input Output PROCESSOR CD-R/MD AUX2 TAPE AUX1 TUNER PHONO NOTE: Turn the knobs on the speaker terminals by hand. (Do not use a tool to turn the knobs.)
  • Page 17   ∼ Figure 2 PM7200(SPEC, ILLUST) Page 36 03.12.17, 11:21 AM Adobe PageMaker 6.5J/PPC...
  • Page 18 You can find your nearest authorized distributor or dealer on our website. JAPAN Marantz Japan, Inc. U.S.A. Marantz America, Inc. EUROPE Marantz Europe B.V. Printed in China PM7200U(表1,表2,表4,他) Page 5 35-1 Sagami Ohno 7-Chome, Sagamihara-shi, Kanagawa 228-8505, Japan 1100 Maplewood Drive, Itasca, IL 60143, U.S.A.

Table of Contents