Installation; Schematic Diagram Showing The Dispensing Module; Fitting The Dispensing Module; Wall Mounted - Miele DOS G 80 Fitting Instructions Manual

Dispensing module
Hide thumbs Also See for DOS G 80:
Table of Contents

Advertisement

Available languages

Available languages

Wall
mounted:
Surface
mounted:

Schematic diagram showing the dispensing module

 Dispensing problems caused by fitting the canister incorrectly.
The canister must not be placed on top of or above the machine.
Make sure that the dispensing hose is not kinked or trapped.
Place the canister on the floor next to the machine or inside an ad-
jacent unit.

Fitting the dispensing module

The dispensing module is supplied with two screws (4.2 x 25 mm)
and two plugs (6 mm) for fitting.
Select a suitably accessible position, e.g. on an adjacent wall or in-
side a unit, for fitting the dispensing module.
Using the drawing as a guide, fit the screws the correct distance
apart (80.0 mm) and suspend the dispensing module from these.
Two slots 76.0 mm apart are provided at the bottom of the dispensing
module for fixing the module to a thin carrier or plate. Screws 3.9 mm
in diameter (not supplied) are required to secure the module.
Drill two holes through the plate and screw the module firmly in
place from underneath.
en - Installation
19

Advertisement

Chapters

Table of Contents
loading

Table of Contents