Head Array - Quantum Q-LOGIC 3 Programming Manual

Hide thumbs Also See for Q-LOGIC 3:
Table of Contents

Advertisement

Programming 3-Switch Head Array
1. Parameter Settings/Program Adjustments
2. Enhanced Display or SCIM
3. Input Configuration
Set Ed Input Configuration to 3-Switch Head.
Click on the little arrow at the bottom of the screen
next to "Programming Mode" to reset the system for
driving. The system is now ready to drive.
Programming Mode
See page 33.
Programming i-Drive 4 Head Array
1. Parameter Settings/Program Adjustments
2. Enhanced Display or SCIM
3. Input Configuration
Set Ed Input Configuration to 3-Direction Prop.
Head Switch Operation.
Click on the little arrow at the bottom of the screen
next to Programming Mode to reset the system for
driving. The system is now ready to drive.
Programming Mode
See page 33.
Programming Toggle Command
Toggle command allows the end user to reverse the arrow's
direction. The Toggle Command is enabled at a default set-
ting during initial programming; however, the timing for some
end users may require adjustment. The Toggle Command
Time, which works on a slide bar, is the amount of time that
the end user needs to flip the directional arrow from front to
back. A command longer than the default Toggle Command
Time is considered by the system as a drive command,
causing the power chair to move.
1. Parameter Settings/Program Adjustments
2. Enhanced Display or SCIM
3. 3-Direction Arrow Toggle Settings
4. Toggle Command Time
Programming Device Double Command
Device Double Command allows the end user to give either
a double left or double right command on their head array
and it will change the mode.
1. Parameter Settings/Program Adjustments
2. Enhanced Display or SCIM
3. Device Options/Timing
Device Double Command, there will be a drop
down menu.
From there either Enable Left or
Enable Right can be selected.
Click on the little arrow at the bottom of the screen
next to Programming Mode to reset the system for
driving. The system is now ready to drive.
Programming Mode
See page 33.
Programming Double Command Timing
Double Command Time is the time the end user has to pro-
vide a double command. There are two ways this can be
accomplished.
1. Parameter Settings/Program Adjustments
2. Enhanced Display or SCIM
3. Device Options/Timing
Double Command Time: Can be programmed by
using the slide bar.
Teach Double Command: Allows the end user to
give the command they can comfortably do when
the Start icon is pressed. That time can be captured
and be set as the Double Command Time.
Programming Mode Jack Configuration
There are two configurations that the mode jack can be
programmed for in Q-Logic 3. The first is Jack Configuration
which allows the mode jack to use a short, double, and
long command. Mapped IO allows other features to be
programmed, such as power seat functions, mouse clicks,
and shortcuts such as HOME and Auxiliary Functions.
1. Parameter Settings/Program Adjustments
2. Enhanced Display or SCIM
3. Switch Options/Timing
Mode Jack Configuration Type (Can be set to Jack
Configuration or Mapped IO).
Programming Mapped IO
Programming the Mapped IO in the Econ-W requires going to
MIO Support located on the top tool bar of the programming
station. This is where custom programming can be done to
the electronics to better fit the end user's needs.
1. MIO Support
2. Mapped I/O
3. Click on the
sign to start a new mapping.
Select Device.
Select Input (which will be Mode Jack on the Display
for instance.
Select Output (which will be the custom function.
(Repeat for other mappings if needed).
Click on the Save Icon

HEAD ARRAY

9
.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents