Download Print this page
Apator ULTRIMIS UL2,5 Installation & Operating Manual

Apator ULTRIMIS UL2,5 Installation & Operating Manual

Water meter

Advertisement

Quick Links

ULTRIMIS WATER METER INSTALLATION & OPERATING MANUAL
WATER METER TYPE
Ultrasonic water meters
with copper body and
integrated RF connectivity
Ultrimis UL
DN15-50
CE, MID, IP68, WM-Bus, LoRaWAN
SHIPPING AND STORAGE
Protect against shocks and vibration.
Store between 0°C and 25°C.
BASIC INFORMATION
Max water temperature 70°C
Ambient temperature 5-55°C
Operating pressure 16 bar*
Battery life 16 years max.**
Two integrated 3.6 V DC lithium batteries,
size AA
RF connectivity
868 MHz up to 25 mW E.R.P.
parameters:
434 MHz up to 10 mW E.R.P.
Communication
WM-Bus, OMS-compliant
standard:
LoRaWAN V1.0.4-compliant
* 10 bar is available on special order.
** Depending on the configuration and ambient
conditions.
ESSENTIAL INSTALLATION COMPONENTS
Apator Powogaz half unions
CLASSIFICATION OF ENVIRONMENTAL CONDITIONS
- Environmental classification – Climate and mechanical conditions: Class B (EN ISO 4064: 2014)
- Environmental classification – mechanical conditions: Class M1 (Directive 2014/32/UE of 26 February 2014)
- Electromagnetic conditions: Class E1 & E2 (EN ISO 4064: 2014 and Directive 2014/32/UE of 26 February 2014)
COMPATIBILITY AND INSTALLATION REQUIREMENTS
Ultrimis UL, UL-01
Ultrasonic water meters
with composite body and
integrated RF connectivity
Ultrimis UL-01
DN15-20
CE, MID, IP68, WM-Bus, LoRaWAN
EU 868MHz
WM-Bus
03A
NFC
ACCESSORIES
Smartphone
Android, NFC
Smartphone app
Android, NFC
DN 15 mm kit of half unions w/gaskets
DN 20 mm kit of half unions w/gaskets
DN 25 mm kit of half unions w/gaskets
DN 32 mm kit of half unions w/gaskets
DN 40 mm kit of half unions w/gaskets
orientation
Available for 433 MHz or 868 MHz service, de-
pending on the water meter's RF module version
Ultrimis
UL2,5
DN15
17
UL2,5-01
DN15
17
UL4
DN20
20
UL4-01
DN20
20
UL6,3
DN25
36
UL10
DN32
44
UL16
DN40
50
UL25
DN50
24
*** The actual installation may feature other connection fitting dimensions.
Flanged DN50 port gasket acc. to PN-EN 1514-1:2001
61
61
107
107
G
g
d
¾"
½"
17 mm
1"
¾"
23 mm
1¼"
1"
29 mm
1½"
1¼"
36 mm
2"
1½"
41 mm
Operating
U
D
U0 D0
TestBox
***
29
25 Nm
29
15 Nm
36
30 Nm
36
20 Nm
47
35 Nm
54
40 Nm
67
45 Nm
24
-
L
Index
37.5
0616-100-018
45.5
0616-100-019
46.5
0616-100-021
56.0
0616-100-026
67
0616-100-020
M
U
D
nx
nx
U5 D3

Advertisement

loading
Need help?

Need help?

Do you have a question about the ULTRIMIS UL2,5 and is the answer not in the manual?

Questions and answers

Summary of Contents for Apator ULTRIMIS UL2,5

  • Page 1 LoRaWAN V1.0.4-compliant * 10 bar is available on special order. ** Depending on the configuration and ambient conditions. ESSENTIAL INSTALLATION COMPONENTS Index Apator Powogaz half unions DN 15 mm kit of half unions w/gaskets ¾” ½” 17 mm 37.5 0616-100-018 DN 20 mm kit of half unions w/gaskets 1”...
  • Page 2 Collector data EU 868MHz WM-Bus reading system Stationary data reading External module TestBox Verification * For WM-Bus only Data register reading Test Remote reading Configuration Apator Powogaz S.A. has the right to modify and improve the manufactured equipment without prior notice.

This manual is also suitable for:

Ultrimis ul2,5-01Ultrimis ul4Ultrimis ul4-01Ultrimis ul6,3Ultrimis ul10Ultrimis ul16 ... Show all