Logging Into The Wbm - Siemens SIMATIC CloudConnect CC7 Series Operating Instructions Manual

Industrial ethernet
Table of Contents

Advertisement

First connection setup with preset IPv4 address
Use the following preset IPv4 address of the gateway during the first connection setup:
● P2 interface address: 192.168.0.55
Note
IP address of the CP
By default, the DHCP client of the gateway is disabled. Make sure that the PC has a fixed IP
address during the first connection setup and that it is located in the same subnet as the
connected interface of the gateway.
When using a DHCP server you do not need to specify the addressing on the PC to be
connected. When it is connected to the network, the PC is assigned an address.
Connection to the Web server of the gateway
Follow the steps below to connect the PC to the Web server of the gateway:
1. Open the Web browser.
2. Enter the IP address of the gateway in the address line of the Web browser:
– https://<Address>
With HTTPS connections when you log in, a warning can appear that the Web page is
not secure or that the certificate is not trustworthy. If you are sure that you have entered
the correct address, ignore the message. If necessary add the connection to the
exceptions (depending on the Web browser).
When the connection setup is successful, the logon window of the WBM opens.
4.4.2

Logging into the WBM

HTTPS connection
Only HTTPS connections are supported.
You can establish a connection between a PC and the WBM of the device.
Changing standard user data
Note
Changing standard user data
For security reasons, the factory set user data (user name, password) of the standard user
must be changed when you log in the first time, see section User (Page 114).
SIMATIC CC7
Operating Instructions, 10/2019, C79000-G8976-C503-02
Configuration
4.4 Calling the WBM
53