Advertisement

Quick Links

IQAN-G12
Instruction book
Publ no MSG33-8418-IB/UK
Edition 2022-06-14

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IQAN-G12 and is the answer not in the manual?

Questions and answers

Summary of Contents for Parker IQAN-G12

  • Page 1 IQAN-G12 Instruction book Publ no MSG33-8418-IB/UK Edition 2022-06-14...
  • Page 2: Table Of Contents

    Mounting the IQAN-G12 ........
  • Page 3 Appendix D ........... 30 Dimensioning of the IQAN-G12 module ......30...
  • Page 4: Publication History

    The user must analyze all aspects of the applica- tion, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or autho- rized distributors.
  • Page 5: Introduction

    (MPE). Contains transmitter FCC ID: QOQ-BGM220S2 IQAN-G12 complies with IC radiation exposure limits set forth for an uncontrolled environment and meets RSS-102 of the IC radio frequency (RF) Exposure rules. This equipment has very low levels of RF energy that it deemed to comply without maximum permissive exposure evaluation (MPE).
  • Page 6: Precautions

    Operation IQAN-G12 receives and transmits radio frequency energy while switched on. Follow any special regulations and always switch off the IQAN-G12 wherever forbidden, or when you suspect that it may cause interference or danger. Disposal Observe your local/national regulations when disposing the device and its package.
  • Page 7 Additional information for diagnosing the system For information, see Appendix B, on page 18, in this document. OTICE It is required to download the operating system 6.08 or later to enable the full functionality of the IQAN-G12 in IQANdesign platform systems. Instruction book, IQAN- G12...
  • Page 8: Quick Start Guide

    000000. IQANdesign set up for IQAN-G12 support. To use full functionality on the IQAN-G12, it should be added as a G1x module, in IQANdesign 6.08 or newer. IQAN-G12 will work in system that support IQAN-G11 (Software from IQANdesign 4.01 and newer), with the limitation that pairing passkey is fixed at 000000 and device...
  • Page 9 Operators can acknowledge the request for a remote diagnostics connection when it is safe and convenient. Set security property to "ask user" to use IQAN-G12 and IQANconnect.Security settings for Master units without a display need to be set up to: •...
  • Page 10: Product Description

    The communication interfaces are used for uploading/downloading applications or diagnostics and typically communicate with an IQAN master module. The IQAN-G12 has 1 CAN interface. It is located in the Deutsch DT 4 pin connector and is used to interface with IQAN master modules (e.g. IQAN-MD4).
  • Page 11: Can Fd

    The IQAN-G12 have the capability to use CAN FD (flexible data-rate) with speeds up to 500/2000 kbps. Bluetooth The IQAN-G12 has an embedded Bluetooth 5.2 low energy, and is suitable for use with a smartphone or tablet with IQANgo or PC with IQANrun. System Diagnostics The IQAN-G12 has 1 bi-color LED light on front surface indicating system status and dongle status.
  • Page 12: Markings And Approvals

    Communication Markings and approvals Markings and approvals Declaration of Conformity Instruction book, IQAN- G12...
  • Page 13 Communication Markings and approvals Instruction book, IQAN- G12...
  • Page 14: Mounting

    • Use the supplied connector cover if mounted outdoor for added protection e.g.UV radiation. Mounting orientation of the IQAN-G12. OTICE The IQAN-G12 module must not be placed in any marine related or similar continuously damp environment without external protection. Instruction book, IQAN- G12...
  • Page 15 Mounting the IQAN-G12 Mounting IQAN-G12 connector cover. Instruction book, IQAN- G12...
  • Page 16: Installation

    Connector Installation Installation Connector Connector kit Parker no. 5031113 Housing DT06-4S Wedge Sockets 1062-16-0122 Connector pin assignments Logical (I)nput or Function description Symbol (O)utput and/or Signal name(s) -BAT Power supply, negative ground +BAT Power supply, positive CAN-L CAN low CAN-H...
  • Page 17: Supply Voltage

    1 A (Fast) is being used. If this fuse is not used, polarity reversal can damage the unit. OTICE IQAN-G12 does not have load-dump protection and must be mounted within approx 2 meters from a unit with load-dump protection. Instruction book, IQAN- G12...
  • Page 18: Communication

    A connection will be charged against your IQANconnect subscription whenever you initiate communication with a system. CAN termination If the IQAN-G12 is located at the end of the CAN bus, it must have a termination resistor installed to terminate the bus. IQAN-G12 CAN-H pos.
  • Page 19: Start-Up

    Start-up procedures Start-up Start-up Start-up procedures This chapter contains instructions for action to be taken in connection with the initial start. ARNING Risk of injury! If the control system is not fitted properly, the machine could move uncontrollably. The machine’s engine shall not be started before the control system is completely fitted and its signals are verified.
  • Page 20: System

    Appendix A Appendix A IQAN-G12 Technical Overview System Operating temperature -30 to 70 °C Absolute maximum temperature -40 to 85 °C Storage temperature -40 to 85 °C Voltage supply 12 or 24 VDC nominal voltage Voltage range 9 to 32 V Power-on threshold typ 6.5 V...
  • Page 21: Bluetooth

    Output power 0,6 mW Range Normal up to 30m Data rate up to 2Mbit/sec (250kbps CAN is limiting this) CAN specification 2.0B and FD CAN bus speed 250 kbit (2.0B) and 500 kbit/2Mbps (CAN-FD) Protection SCB, SCG Instruction book, IQAN-G12...
  • Page 22: Led Messages And Actions

    100 ms off Error Error Primary Flash (red) Secondary Flash (yellow) code Error category Error description CAN error (bus off) Internal error a. IQAN-G12 will attempt to recover automatically. b. Followed by a longer sequence of flashes, contact Parker. Instruction book, IQAN-G12...
  • Page 23 IQANrun. It has key features such as system info, log management, measure, adjust and sending and receiving files. IQANgo connects to an IQAN system using WiFi, Bluetooth or Internet. IQANgo and IQAN-G11 /-G12 Bluetooth to CAN adapter Instruction book, IQAN-G12...
  • Page 24: Iqango Modes Together With The Iqan-G11 /-G12

    • On site mode –the IQANgo app is connected to the system via the Bluetooth gate- way (IQAN-G11 or IQAN-G12). The IQANgo app user performs all operations. • Remote assistance mode – the IQANgo app together with the Bluetooth gateway connects the machine to internet, making the IQAN system available to remote sup- port via the IQANconnect service.
  • Page 25: On Site Mode

    The method for enabling pairing is configured in IQANdesign. If pairing is required the pairing dialog will be shown, requesting a 6 digit passkey. This passkey is depending on the configuration set in IQANdesign. Also see the IQANrun user manual section on Bluetooth. Instruction book, IQAN-G12...
  • Page 26: Login

    On site mode Appendix C Login Start IQANgo, follow the steps below: Tap ”Log in” Enter user name and password Buttons for System, Log, Measure (if not already connected, and Adjust show up connection dialog will show) Login Instruction book, IQAN-G12...
  • Page 27: View System Info

    Select module to view module info and errors System info View logs Start IQANgo. Connect. Select Logs. Select log Save or Mail log Logs Logs can also be retrieved using the Get logs operation on the main menu. Instruction book, IQAN-G12...
  • Page 28: Measure

    On site mode Appendix C Measure Start IQANgo. Connect. Select Measure. Select Measure group Graph measure Start/Stop graph measure Save or Mail measurement Measure Instruction book, IQAN-G12...
  • Page 29: Adjust

    There is no need to acknowledge the new value you have adjusted it. Also see the section on System diagnostics in IQANrun user manual for more details. Instruction book, IQAN-G12...
  • Page 30: Send To Machine

    • A dialog will show information about the file you are about to send. • A dialog will ask you to confirm that the machine is not moving and engine is off • If needed, enter user name and password • Wait for the update to complete Instruction book, IQAN-G12...
  • Page 31: Get From Machine

    Use the menu button to email file Enter a file name (if not already connected, connection dialog will show) Get from machine For more details on lone files and settings files, see Get operations in IQANrun user manual. Instruction book, IQAN-G12...
  • Page 32: Manage Files

    Select the file you want to work with Press the menu button Select Mail or Delete Manage files Files are stored locally on the device in the IQANgo folder Android folder is Documents > IQANgo Files iOS folder is On My iPhone > IQANgo Instruction book, IQAN-G12...
  • Page 33: Remote Assistance

    The IQANconnect key that is shown in the IQANgo Remote assistance menu is unique to your phone. If you connect a different machine to Internet using IQANgo using the same phone, the same IQANconnect key will be used. Also see the IQANrun user manual section on Remote assistance. Instruction book, IQAN-G12...
  • Page 34: Dimensioning Of The Iqan-G12 Module

    Dimensioning of the IQAN-G12 module Appendix D Appendix D Dimensioning of the IQAN-G12 module 37,6 27,75 Unit = mm Instruction book, IQAN-G12...
  • Page 35 Dimensioning of the IQAN-G12 module Appendix D Dimensioning of the IQAN-G12 module with connector cover Unit = mm Instruction book, IQAN-G12...
  • Page 36 For latest information visit our website www.iqan.com Information in this instructionbook is subject to change without notice Publ no MSG33-8418-IB/UK Edition 2022-06-14 Parker Hannifin Parker Hannifin Mobile Systems Division Electronic Controls Division SE-435 35 Mölnlycke 1651 N. Main Street Sweden...

Table of Contents