pow (control voltage display)
pow
err
The "pow" LED indicates the state of the control voltage.
OFF
Flashes slowly (0.5 Hz)
Flashes briefly (3 Hz, 30 ms
ON)
ON
err (error display)
pow
err
The error LED (err) indicates errors.
OFF
Flashes slowly (0.25 Hz)
Flashes slowly (0.5 Hz)
Flashes quickly (2 Hz)
Flashes long
Flashes for a long time (0.5
Hz, 1.8 s ON)
Flashes quick
Flashes briefly (3 Hz, 30 ms
ON)
ON
bus err (SERCOS bus error display)
bus
err
The error LED (err) indicates errors.
OFF
ON / Flashes
slnk (SERCOS link display)
sInk
serr
The "slnk" LED indicates the state of the SERCOS bus (to X7 SERCOS via copper
cable).
OFF
ON
ELAU AG
Control voltage (24 V) is missing or is too low, not ready, fatal system
error
Bootloader is active, firmware is defective
(Flashes in sync with err LED).
Identifying the device (IdentifyDevice parameter)
(Flashes in sync with err LED).
Device ready, error diagnosis by means of PacDrive controller possible
No error
SERCOS error
Bootloader is active, firmware is defective
(Flashes in sync with pow LED).
General error or device not entered in the PLC configuration as a real
device.
SERCOS ring interruption
Identifying the device (IdentifyDevice parameter)
(Flashes in sync with pow LED).
Fatal system error
Normal operation
Bus error (problem with fiber-optic cable connection, e.g. transmitting
power is too low or too high, cable break, etc.)
SERCOS ring break
SERCOS ring OK
PacDrive Power Supply PS-5 and Distribution Box DB-5

4.1 Indicators and control elements

Page 17

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PacDrive PS-5 and is the answer not in the manual?

Questions and answers

Related Products for ELAU PacDrive PS-5

This manual is also suitable for:

Pacdrive db-5

Table of Contents

Save PDF