Download Print this page
Sealey PBS90.V2 Quick Start Manual

Sealey PBS90.V2 Quick Start Manual

Industrial hydraulic pipe benders with stand 9tonne / 15tonne

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear eye
instruction
protection
manual
1. SAFETY
Ensure the pipe bender is in sound condition and good working order. Take action for immediate repair or replacement of damaged
9
parts. Use recommended parts only. The use of improper parts may be dangerous and will invalidate the warranty.
Keep pipe bender and associated parts clean for best and safest performance.
9
Locate the pipe bender in a suitable, well lit working area.
9
Keep working area clean, tidy and free from unrelated materials.
9
Use on level and solid ground, preferably concrete.
9
Ensure all non-essential persons keep a safe distance whilst the pipe bender is in use.
9
Wear appropriate safety equipment, including eye protection, ear protection, protective gloves and safety footwear.
9
WARNING! Cut pipe edges may be sharp, take care when handling any cut steelwork.
Check that bending die is correctly seated on ram and that the roller shafts are fully engaged in the frame and pinned before operating hydraulic unit.
9
Keep hands away from die and rollers when bending pipe.
9
Use a qualified person to lubricate and maintain the hydraulic unit.
9
Confirm that the recommended hydraulic oil is used during maintenance.
9
DO NOT top up system with brake fluid. Use hydraulic oil only.
8
DO NOT operate the pipe bender if damaged.
8
DO NOT allow untrained persons to operate the pipe bender.
8
DO NOT exceed the rated capacity of the hydraulic unit (see Section 3).
8
DO NOT use the pipe bender for purposes other than that for which it is intended.
8
DO NOT alter the pressure control valve.
8
When not in use, store pipe bender, with the hydraulic ram in the down position, in a dry, childproof area.
9
When using hydraulic type pipe benders, the bent pipe or tube is prone to deformation on both the inside and
outside curvature.
The pipe or tube can be deformed into an oval shape or creased depending on the wall thickness of the material.
This is not a fault and largely unavoidable. Consider packing the pipe or tube with dried sand or similar medium
before bending as this may help to alleviate deformation of the pipe or tube. Pack the sand tight and cap both ends.
2. INTRODUCTION
PBS91.V4
Tripod mounted pipe bender suitable for bending pipes up to 180°. Integral 15tonne ram. Suitable for bending DIN classified medium and heavy pipe.
2-Speed hydraulic pump gives fast pipe positioning and the power to bend 75mm pipe. Supplied with eight (15mm(1/2") - 75mm(3") interchangeable
pipe dies and packed in a heavy wooden crate for easy transportation.
PBS90.V2
Tripod mounted pipe bender suitable for bending pipes up to 180°. Integral 9tonne ram. Suitable for bending DIN classified medium and heavy pipe.
2-Speed hydraulic pump gives fast pipe positioning and the power to bend 50mm pipe. Supplied with six (15mm(1/2") - 50mm(2")) interchangeable
dies. Packed in a heavy wooden crate for easy transportation.
3. SPECIFICATION
Die Sizes:
Height:
Maximum Load:
Maximum Pipe Diameter:
© Jack Sealey Limited
INDUSTRIAL HYDRAULIC PIPE BENDERS WITH
STAND 9TONNE / 15TONNE
MODELS NO:
Wear ear
Wear protective
protection
gloves
PBS90.V2
15mm(1/2"), 20mm(3/4"), 25mm(1"), 32mm(1-1/4"),
40mm(1-1/2"), 50mm(2")
700mm
9tonne
50mm
Original Language Version
PBS90.V2, PBS91.V4
Wear safety
Warning!
footwear
PBS91.V4
15mm(1/2"), 20mm(3/4"), 25mm(1"), 32mm(1-1/4"),
40mm(1-1/2"), 50mm(2"), 63mm(2-1/2"), 75mm(3")
700mm
15tonne
75mm
PBS90.V2, PBS91.V4 Issue:3 (2,H,F)
04/08/22

Advertisement

loading

Summary of Contents for Sealey PBS90.V2

  • Page 1 PBS90.V2, PBS91.V4 MODELS NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 Open the release valve and the piston will retract under spring tension. Raise upper plate and remove or reposition the pipe as required. 5.9. After use, store the pipe bender with the ram fully retracted and the pumping pistons in the down position. fig.4 fig.3 PBS90.V2, PBS91.V4 Issue:3 (2,H,F) 04/08/22 Original Language Version © Jack Sealey Limited...
  • Page 3 Should you need to replace the oil ensure the piston is fully retracted. An excess of oil will render the press inoperative. Use only appropriate Sealey hydraulic jack oil. DO NOT use brake fluid. Contact your local Sealey stockist for details. Purge the system 6.6.

This manual is also suitable for: