The default value for this parameter is one.
Note:
Field Service Menu Enable [Y/N] = N?
Remote Start Method Switch [G/M/B/N] = B?
The Remote Start Method Switch is used when the MVME5100 is
cross-loaded from another VME-based CPU in order to start execution
of the cross-loaded program.
Probe System for Supported I/O Controllers [Y/N] = Y?
http://www.motorola.com/computer/literature
The bug does not automatically acquire all of the memory it is
allowed. It accumulates memory as necessary in one megabyte
blocks.
Y
Display the field service menu.
Do not display the field service menu. (Default)
N
Use the Global Control and Status Register to pass
G
and start execution of the cross-loaded program.
Use the Multiprocessor Control Register (MPCR) in
M
shared RAM to pass and start execution of the cross-
loaded program.
Use both the GCSR and the MPCR methods to pass
B
and start execution of the cross-loaded program.
(Default)
Do not use any Remote Start Method.
N
Accesses will be made to the appropriate system
Y
buses (e.g., VMEbus, local MPU bus) to determine
the presence of supported controllers. (Default)
N
Accesses will not be made to the VMEbus to
determine the presence of supported controllers.
Default Settings
3-9
3