3. Inspection on the built-in ELB
Inspect the built-in ELB (once a month) to avoid a hazard to users such as damage to property, serious injury or
death.
• Make sure the appliance is in on condition.
• Press the ELB Test Button. If the ELB is in normal condition, ELB Reset Knob will slide down.
• Push up the ELB Reset Knob to reset the ELB.

TROUBLESHOOTING

1. Check the following points before asking for repair.
Symptom
Water is not drawn normally.
Water is not hot enough.
No hot water comes out from the
Water Outlet.
(no electrical supply to the
appliance)
No water fl ows out from the
appliance at all.
2. If abnormalities as mentioned below are found during use, do not use the appliance and contact an authorized
dealer immediately.
• Water leakage.
• Water temperature cannot be controlled.
• ELB LED does not light up.
3. Special skill is required for repairing. Never try to repair the appliance by yourself.

SPECIFICATIONS

Model No.
Power Supply
Power Consumption
Capacity
Rated Pressure
Dimension (Approx.)
H × W × D
Weight (Approx.)
Empty / Full
Water Proof
DH-30_20_15HAM_ENVT.indb 7
DH-30_20_15HAM_ENVT.indb 7
Points to be checked
Check whether any leakage of the water connections.
Wait until 75 °C LED (orange) is turned off before using the appliance.
• Check whether the water and electrical connections comply with the Specifi cations
as indicated and check the phase continuity between the terminals. If there is no
continuity, probably the ON/OFF DP (Double Pole) Switch has been activated.
• Make sure to switch on the ON/OFF DP (Double Pole) Switch.
• Make sure to switch on the Miniature Circuit Breaker (MCB).
• Make sure the ELB Reset Knob is not slide down.
• Push up the ELB Reset Knob to reset the ELB (refer to "TEST OPERATION" at
page EN12).
• Make sure the Main Water Valve is opened.
• Check whether the water supply is there.
• Check whether inlet water supply connected to the Safety Valve.
DH-30HAM
30 L
323 mm x 704 mm × 310 mm
10 kg / 40 kg
DH-20HAM
220 V a.c. 50 Hz
2500 W
20 L
0.75 MPa / 7.5 bar / 108.78 psi
323 mm × 526 mm × 310 mm
8 kg / 28 kg
IPX4
DH-15HAM
15 L
323 mm x 437 mm × 310 mm
7 kg / 23 kg
EN7