Toshiba TCB-SIR41UYP-UL Installation Manual page 2

Occupancy sensor kit

Advertisement

Available languages

Available languages

CODE No. (DN) setting
■ Wired remote controller (RBC-AMS5 E-UL)
Perform the advanced settings for the air conditioner. Carry out the setting operation
while the indoor unit is stopped. (Turn off the air conditioning unit before starting the
setting operation.)
Display example of
AMS5 E-UL
1. Push the [
MENU] button to display the menu screen.
2. Push and hold the [
MENU] button and the [
to display the "Field setting menu".
Push and hold the buttons for more than 4 seconds.
DN setting
Code
(DN)
Data
B5
0000
Return
Fix
<
>
3. Push the [
] / [
"Field setting menu" screen, then push the "
The fan and louver of the indoor unit operate. When the group control is used, the
fan and louver of the selected indoor unit operate.
Move the cursor to select "DN code" with the "
set "B5" with the [
] / [
Move the cursor to select "data" with the "
"0001" with the [
] / [
Return
Yes
4. Push the [
MENU] button to set the other DN codes. After "Continue?" is
displayed on the screen.
5. Push the "
No" [
No
" " appears on the screen for a while, then the screen returns to the "Field setting
menu" screen.
Pushing the "
No" [
No
when the group control is used. Push the [
selection screen to finish the setting operation. " " appears on the screen for a
while, then the screen returns to the "Field setting menu" screen.
6. Push the [
CANCEL] button to return.
Field setting menu(2/2)
Field setting menu(2/2)
6. Setting timer operation mode
6.Setting timer operation mode
7. DN setting
7.DN setting
8. Reset power consumption data
8.Reset power consumption data
Return
Return
Set
Set
] button at the same time
DN setting
Code
(DN)
Data
B5
0001
Return
Fix
<
] button to select "7. DN setting" on the
Set" [
F2] button.
Set
<
<
" [
] button.
>
" [
F2] button, then set
>
] button.
DN setting
Continue?
No
F2] button to finish the setting operation.
F2] button displays the unit selection screen
CANCEL] button on the unit
About the occupancy sensor
• Sometimes the sensor may not detect people even when they are present if their
movements are small.
• If something having a difference in temperature with the surroundings moves, the
sensor may detect people as present even if they are not present.
• A wired remote controller (RBC-AMS5 E-UL) is required to use an occupancy
sensor.
• Be sure to install an occupancy sensor in all indoor units if using group operation.
List of separately available products that cannot be used with
the occupancy sensor
The following separately available products cannot be used together with the
Occupancy sensor.
Product name
Wireless receiver kit
Air purifier kit
>