Philips 32PFS5709/12 Service Manual page 33

Chassis tpm14.2e la
Hide thumbs Also See for 32PFS5709/12:
Table of Contents

Advertisement

4.5.2
AmbiLight Panel
Refer to
Figure 4-35
for details.
1. Gently release the clamps and unplug the two connectors
[1, 2,3] that secure the ambilight panels. Release the clips
3
4.5.3
Small Signal Board (SSB)
Refer to
Figure 4-36
for details.
Caution: it is mandatory to remount all different screws at their
original position during re-assembly. Failure to do so may result
in damaging the SSB.
1. Release the clips from the LVDS connector that connect
with the SSB [1].
Caution: be careful, as these are very fragile connectors!
2. Unplug all other connectors [2].
3. Remove all the fixation screws from the SSB [3].
4. The SSB can now be shifted from side connector cover,
then lifted and taken out of the I/O bracket. Refer to
Figure 4-36
for details.
Mechanical Instructions
1
Figure 4-35 Rear cover removal [1]
back to
div. table
TPM14.2E LA
from the FFC connector that connect with the AmbiLight
control panel [3].
2. Lift the AmbiLight panel from the rear cover. Make sure that
wires and flat foils are not damaged while lifting the
ambilight panel from the rear cover.
3
1
2
3
Figure 4-36 SSB removal
4.
EN 33
2
19613_106.eps
3
3
19613_107.eps
2014-Sep-26

Advertisement

Table of Contents
loading

Table of Contents