Term or abbreviation
MODULE CHECK FAIL
ECP
HARDWARE FAIL
INH LATCH
INH LIVING
UVP PROT
OVP PROT
OCP PROT
OPP PROT
UCP PROT
OTP PROT
SENSE PROT
SRVS PROT
ORVS PROT
FIBER MULTI MASTER
FIBER EXT UNLOCK
Copyright © Itech Electronic Co., Ltd.
Description
Module detection failed
Current equalization
protection
Hardware fault
Disable output, turn off the
output.
Disable output, turn on the
output.
Undervoltage protection
Overvoltage protection
Overcurrent protection
Over power protection
Undercurrent protection
Over temperature protection
Sense abnormal protection
Sense reverse protection
Output reverse connection
protection
Multi-master conflict
The outer ring of the fiber is
not locked.
Appendix
How to do
Re-check after
power-off restart. If
it still fails to check,
please contact
ITECH authorized
dealer or ITECH
technical support.
For details, see
5.11.5 IO–5. INH-
Living,
Not-Invert.
For details, see
4.5
Protection Function
for Power
Supply.
Reconnect the test
cables.
When multiple mas-
ter unit are con-
nected in parallel,
multiple Masters
are set in System
menus. Just set 1
Master, and the oth-
er units are Slave.
Fiber multi-master
parallel: set the par-
allel in the System
menu in turn. For
details, see
5.10
236
Need help?
Do you have a question about the IT6000C Series and is the answer not in the manual?