C4 Sealing disc C2 Screw ring C5 Bottle C3 Teat Accessories There are multiple versions of this breast pump package, which all come with a different combination of the following Philips Avent accessories: Travel bag Breast milk storage bags* Cleaning brush...
Page 4
Do not use the breast pump if the silicone diaphragm appears to be damaged or broken. See chapter ‘Ordering accessories’ for information on how to obtain replacement parts. Only use accessories and parts recommended by Philips Avent. No modification of the breast pump is allowed. If you do so, your warranty becomes invalid.
Page 5
Cleaning and disinfecting Overview Clean and disinfect the parts that come into contact with the breast and breast milk as described below: When Disassemble all parts and then clean them as Clean and disinfect before first use and after every use. described in chapter 'Cleaning' and disinfect them as described in chapter 'Disinfecting'.
Page 6
Step 2: Cleaning The parts that come in contact with milk can be cleaned manually or in the dishwasher. Warning: Do not use antibacterial or abrasive cleaning agents to clean the breast pump parts as this may cause damage. Caution: Never put the motor unit or the adapter in water or in a dishwasher, as this causes permanent damage to these parts.
Page 7
Cushion size The Philips Avent single/double electric breast pump has a soft, active cushion. It gently stimulates your nipple to trigger milk flow. The cushion is made of flexible silicone, that adapts to up to 99.98 % of women, fitting nipple sizes up to 30 mm.
Page 8
1. Wash your hands thoroughly 2. Push the white valve in the 3. Screw the pump body onto 4. Place the cushion in the with soap and water. pump body as far as possible. the bottle. pump body and make sure that the rim covers the pump body.
Page 9
Motor unit part description USB power inlet On/off button with pause/play function Mode selection button 'Level down' button 'Level up' button Indicator lights for modes and levels Tubing port for single breast pump Tubing ports for double breast pump Mode indicator lights The breast pump has two modes.
Page 10
Warning: If the process becomes very uncomfortable or painful, stop using the pump and consult your healthcare professional. Note: If you regularly express more than 125 ml/4 fl oz per session, you can purchase and use a 260 ml/9 fl oz Philips Avent Natural bottle to prevent overfilling and spillage.
Page 11
Warning: Refrigerate or freeze expressed milk immediately or keep it at a temperature of 16-29 °C (60-85 °F) for a maximum of 4 hours before you feed your baby. For more information about the breast pump and tips for expressing milk, visit www.philips.com/avent. Storing breast milk...
Page 12
Feeding breast milk with the bottle For your child’s safety and health WARNING! Continuous and prolonged sucking of fluids will cause tooth decay. Always check food temperature before feeding. Throw away at the first signs of damage or weakness. Keep components not in use out of the reach of children. Never attach to cords, ribbons, laces or loose parts of clothing.
Page 13
When you order spare teats, make sure that you use a teat with the correct flow rate for your baby (see ‚Choosing the right teat for your baby‘) and do not mix Philips Avent Anti-colic bottle parts and teats with parts of the Philips Avent Natural bottles. They do not fit and could cause leakage or other issues.
- If you are using the Philips Avent breast pump for the first time, you may need some practice before you are able to express any milk. More expressing tips can be found on the Philips Avent website www.philips.com/avent.
Page 15
30 minutes to let it reach a temperature within the usage conditions (5 °C to 40 °C/41 °F to 104 °F) before you use it. Electromagnetic fields (EMF) This Philips device complies with all applicable standards and regulations regarding exposure to electromagnetic fields.
Page 16
Technical information Single electric breast pump Double electric breast pump Vacuum level Stimulation: -60 to -200 hPa (-45 to -150 mmHg) Expression: -60 to -360 hPa (-45 to -270 mmHg) Adjustable in steps of 20 hPa Intermittent vacuum Cycle speed 53-120 cycles/min.
Page 17
Indicates that an object is capable of being recycled - not that the object has been recycled or will be accepted in all recycling collection systems. Indicates 2-year Philips worldwide guarantee. Indicates that a specific adapter is required for connecting the breast pump.