This product is a high-tech infra-red (IR) thermometer energy of IR emitted from the forehead. The product helps you to assess you and your family members' health conditions easily and quickly. Product Name: Infrared No-Touch Forehead Thermometer Product Model: PT3
Safety Precautions
Use of this thermometer is not intended as a substitute for consultation with your physician. Please consult your doctor if you have any doubt about the temperature reading.
For consumer use only, not for professional use.
Keep the thermometer out of reach of children. For accidental swallowing of the battery or other components, please contact emergency services immediately.
Batteries must not be thrown into an open fire or short circuited.
Caution
Measurements
Thermometer readings should be regarded as a reference. Do not attempt self-diagnostics or self-treatment using the temperature readings. Please seek professional medical advice when necessary.
There is no absolute standard for human body temperature. Knowing your own normal body temperature range is important to accurately determine if you have a fever.
Make sure that the forehead of the subject is free from sweat, cosmetics, dirt, or grease before measuring.
Patients should not drink, eat, or be physically active before/while taking a reading. Wait 30 minutes before taking a measurement. Temperature readings taken when a body is in a state of stable equilibrium is more accurate and useful as a reference.
Do not take temperature measurement over scar tissue, open sores or abrasions.
Do not measure body temperature from scar tissues on the forehead as such tissues will affect temperature conduction of the body.
If there is a temperature difference between the thermometer storage area and the new ambient environment around the subject, please let the thermometer sit within the new environment for 30 minutes before taking the measurement.
Do not measure body temperature immediately after consuming a drug that raises body temperature. Temperature readings taken at this time will not be accurate.
It is normal for readings taken from continuous measurements to fluctuate within a small range. During continuous measurements, the subject's body temperature may be transmitted to the thermometer, affecting measurement accuracy. We recommend taking only up to 3 continuous readings within a short period.
Do not directly face the sun or an air outlet of an air conditioning or radiator device during the measurement as this will cause changes to the forehead temperature. Measurements should be taken in a stable environment where possible.
Do not measure body temperature in an environment with strong EM interference (examples include places close to a working microwave, induction cooker, or cellphone in-use) as EM interference may cause errors in the reading or even device failure.
This product should be considered a personal device. Clean and sanitize the product properly to prevent cross contamination.
To clean a dirty thermometer probe, gently swipe the probe using a cotton swab dipped in 75% alcohol. Let the cleaned thermometer sit for at least 15 minutes before taking more measurements.
This infrared thermometer meets requirements established in ASTM Standard (E1965-98) Except of clause 5.2.2. It displays subject's temperature over a range of 89.6 ℉~109.2℉. Full responsibility for the conformance of this product to the standard is assumed by (manufacturer: Famidoc Technology Co., Ltd. Add: No. 212 Yilong Road, Hexi Industrial Zone, Jinxia, Changan Town, Dongguan 523853, Guangdong Province, China.)
About the product
This product is a precision device. Return the product to its original packaging for proper storage after use. To ensure accurate measurements, avoid the device or probe contacting any liquid or droplets. Avoid tiny particles (such as dust or powder) falling into the probe.
Avoid dropping or subjecting the product to external forces. Do not disassemble or re-assemble the product on your own.
Do not directly touch the probe with your fingers or blow on it. Measurements taken using a damaged or dirty IR probe may be inaccurate.
Keep the product at a place inaccessible to children to prevent children from swallowing the batteries or small parts.
Do not throw the thermometer or batteries into fire to prevent explosions.
Remove the batteries from the thermometer if the device will not be used for more than one month.
If you are allergic to plastic/rubber, please don't use this device.
The materials (ABS, TPU, metal) of expect contact with patient had passed the ISO 10993-5 and ISO 10993-10 standards test, no toxicity, allergy and irritation reaction. They are in compliance with the MDD requirements. Based on the current science and technology, other potential allergic reactions are unknown.
Overall Description
The thermometer is mainly comprised of a plastic casing, IR temperature sensor, MCU, vibration motor, LED display screen and batteries.
LED screen instructions Device dimensions: 5.39 in x 1.34 in x 1.54 in Screen dimensions: 1.01 in x 0.75 in Product weight: 90 g
Product performance
Measurement position: Centre of the forehead surface
Measurement distance: ≤1.18in(3 cm)
Power source: DC 3V; 2 x 1.5V AAA batteries
Measurement range: 89.6℉-109.2℉(32℃-42.9℃)
Measurement precision: ±0.4℉ within 95℉-107.6℉, and±0.5℉ for other temperature ranges.
Operation mode: Adjusted mode: forehead Direct mode: surface mode
Expected service life: 2 years
Reference Body Site: Oral
Software version: V1.0
ASTM laboratory accuracy requirements in the display range of 98°F to 102°F(37℃) for IR thermometers is ±0.4°F(±0.2℃), whereas for mercury in-glass and electronic thermometers, the requirement per ASTM Standards E667-86 and E1112-86 is ±0.2°F(±0.1℃).
Expected use and scope of applications
This product mainly uses IR temperature sensing of the forehead to measure human body temperature. Can be used for babies, children, and adults. Babies and children should not operate the thermometer on their own. Body temperature readings for babies and children should be taken by an adult. Reminder: Temperature readings may differ according to skin tone and measurement distance.
Contraindications
It is not recommended for people whose measuring part has local lesions, such as inflammation, trauma, postoperative, etc.
Instruction For Use
The patient is an intended operator. The patient can measure, transmit data and change battery.
Installing the product
Insert the 2 battery cells from the packaging box into the battery compartment at the back of the device. The product will start automatic inspection and a standby mode (if the device indicates low battery power, then replace the batteries to ensure ample power supply).
Measurement process
Aim the thermometer probe at the center of the forehead and keep the probe 1.18in (3cm) away from the forehead (the optimal distance is about the width of an adult's index finger). Do not touch the forehead with the probe.
Gently press the measurement button [] to start the measurement.
The device will vibrate once a reading is obtained. The reading will be displayed on the screen. If the measurement is failed, the device will not vibrate the screen but display [] instead.
Possible reasons for measurement errors include:
Measurement distance is greater than 1.18in (3cm);
Environment temperature does not meet measurement requirements or there is an excessively large temperature difference;
Target temperature exceeds measurement range.
Power off
If no more measuring is required, simply let the device sit idle for 8 seconds to power off automatically.
Unit switching
When the device is powered OFF, press and hold the measurement button for 8 seconds to enter unit switching mode. Under this mode, both ℃ and °F should flash at the same time.
Under this mode, press the measurement button to switch to Fahrenheit or Celsius. The corresponding symbol of the selected unit after switching will flash.
After selecting the unit, press and hold the measurement button for 8 seconds to leave the unit switching mode.
Reminder: If you do not press and hold the measurement button for 8 seconds to confirm the unit selected before the screen switches off, the system will consider the switch as a failure and retain the original unit for temperature measurements.
Installing and replacing batteries
When switched ON for use, the thermometer will automatically detect remaining battery capacity. If battery capacity is low but adequate for measurements, the low power symbol [] will be displayed with the measurement results. However, if the battery capacity is too low for measurements, the screen will display a single, flashing [] icon and automatically switch OFF after 8 seconds. To continue using the device, old batteries must be replaced.
Replacing batteries
Press down and hold the battery cover with the finger and apply some force to slide the cover backwards to open the battery compartment.
Remove the old batteries and install the new batteries.
Refer to the battery polarity symbols to orient the batteries properly during installation. Make sure that the new batteries are tightly inserted into the battery compartment and make sure that the polarity is not reversed during installation.
Return the battery cover to close the battery compartment.
Comply with relevant national laws and regulations when disposing of the used batteries.
Do not dispose of batteries directly into the trash bag.
Remove the batteries if the device will not be used more than one month.
When using, shall not touch battery and the patient simultaneously.
Do not throw batteries into fire.
The typical service life of the new and unused batteries is 300 measurements for the operation time is 60s.
Product errors and troubleshooting
Problem
Item to detect
Solution
Battery depleted
Replace old batteries with new ones
Batteries have been installed with the wrong polarity
Batteries are not installed properly
Take out the batteries and re-install them correctly.
Unable to carry out measurement as current battery capacity is too low.
Replace the batteries
Measurement distance too long
Target temperature is beyond range of measurements 89.6℉- 109.2℉ (32℃-42.9℃)
Environment temperature either exceeds the design range 59℉-104℉ (15℃- 40℃) or is unstable
Follow the instruction manual and repeat the measurements
Current state: All symbols are flashing on the screen. The product is not usable.
Please contact customer services.
Current battery capacity is too low.
Replace the battery as soon as possible.
Body temperature
Body temperature varies from person to person and fluctuates during the course of the day. For this reason, it is suggested to know one's normal, healthy forehead temperature to correctly determine the temperature.
Body temperature runs approximately from 95.9°F to100°F (35.5℃-37.8℃). To determine if one has a fever, compare the temperature detected with the person's normal temperature. A rise over the reference body temperature of 1°F(1℃) or more is generally an indication of fever.
Different measurement sites(rectal, axillary, oral, frontal, auricular) will give different readings. Therefore it is wrong to compare the measurement taken from different sites.
The following are typical temperatures for adults, based on different measurement sites:
Rectal
97.9°F-99.1°F
36.6℃ to 38℃
Axillary
94.5°F-99.1°F
34.7℃ to 37.3℃
Oral
95.9°F-99.5°F
35.5℃ to 37.5℃
Auricular
96.4°F-100.4°F
35.8℃ to 38℃
Care and Cleaning
The probe (comprising a temperature sensor and a distance sensor) is the most intricate part of the thermometer, and should be kept clean and intact to acquire accurate readings. Use the following method to clean the probe: Gently swab the surface of the probe using a cotton bud soaked in > 75% medical alcohol.
If the probe (sensor) is broken, please contact customer services.
Use a piece of soft, dry cloth to clean the display screen and external surface of the thermometer. If the thermometer is very dirty, the cloth can be moistened with some medical alcohol to clean the device.
The product is not waterproof. Do not clean the device with detergents. Do not soak the thermometer in water or other liquids.
Maintenance
This company has not authorized any agency or individual to carry out product repairs or maintenance. Do not attempt to disassemble or modify the thermometer if you suspect functional issues with the device.
The IR thermometer is an extremely precise instrument. Any improper maintenance, disassembly, or modification may lead to inaccuracies of the product measurements.
If you suspect any product issues during the warranty period, please contact customer services for subsequent handling.
Disposal
Dispose of the battery in accordance with the regulation applicable at the place of operation. Dispose of at public collection point in the EU countries – 2002/96/EC WEEE Directive. If you have any queries, please refer to the local authorities responsible for waste disposal.
Notes
Please act according to local laws for disposal of used batteries.
Take out the battery if you are not going to use the unit for a long time.
To protect the environment, dispose of empty batteries at appropriate collection sites according to national or local regulations. Dispose of at public collection point in the EU countries – 2006/66/EC Directive.
Operating, shipping, and storage conditions
Operating conditions
Range of operating environments Temperature: 59℉-104℉ (15℃- 40℃) Humidity: 15-85%RH, non-condensing Atmospheric Pressure: 70kPa~106kPa
Use only accessories provided by the original manufacturer, and check for any missing accessories.
1 IR Thermometer
2 AAA batteries
1 Instruction manual
1 Quick user guide
Standard icons
Attention: Follow instructions for use! (The sign background color: blue. The sign graphical symbol: white.) The batteries and electronic instruments must be disposed of in accordance with the locally applicable regulation, not with domestic waste. Manufacturer information Symbol for "WARNING" Serial number Authorized representative in the European Community IP code of the device: this device's grade of against ingress of solid foreign objects -- ≥ 12.5mm diameter (and the against access to hazardous parts with finger); the grade of waterproof is dripping (15° tilted). Complies with MDD 93/42/eec Requirements
Calibration
The thermometer is initially calibrated at the time of manufacture. If this thermometer is used according to the use instruction, periodic re-adjustment is not required. If any time your question the accuracy of measurement, please contact distributor or manufacturer, the contact information is on the last page.
Storage
Do not put the thermometer under direct sunlight, high temperature, or moist environments. Do not allow it to come into contact with fire or harsh vibrations.
Take out the battery if the device is not used for a long period of time.
Electromagnetic Compatibility (EMC) Tables
Guidance and manufacturer's declaration - electromagnetic emissions
The PT3 device is intended for use in the electromagnetic environment specified below. The customer or the user of the PT3 should assure that it is used in such an environment.
Emissions test
Compliance
Electromagnetic environment-guidance
RF emissions CISPR11
Group 2
The PT3 device must emit electromagnetic energy in order to perform its intended function. Nearby electronic equipment maybe affected.
RF emissions CISPR11
Class B
The PT3 device is suitable for use in all establishments other than domestic and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes.
Harmonic emissions lEC61000-3-2
Not applicable
Voltage fluctuations/flickeremissions lEC61000-3-3
Not applicable
Guidance and manufacturer's declaration — electromagnetic immunity
The PT3 device is intended for use in the electromagnetic environment specified below. The customer or the user of the PT3 should assure that it is used in such an environment.
Immunity test
IEC 60601 Test level
Compliance level
Electromagnetic environment - guidance
Electrostatic discharge(ESD) lEC61000-4-2
±6kV contact ±8kV air
±6kV contact ±8kV air
Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30%.
Guidance and - manufacturer's declaration. Electromagnetic immunity
The PT3 device is intended for use in the electromagnetic environment specified below. The customer or the user of the PT3 should assure that it is used in such an environment.
3V rms 150 kHz to 80 MHz 3V rms 3V/m 3V/m 80 MHz to 2.5 GHz
±6kV contact ±8kV air
Electromagnetic environment - guidance
Portable and mobile RF communications equipment should be used no closer to any part of the PT3 device, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance. d=1.2 √p d=1.2 √p 80MHz―800MHz d=1.2 √p 800MHz―2.5GHz where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters(m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey, a. should be less than the compliance level in each frequency range. b. Interference may occur in the vicinity of equipment marked with the following symbol:
NOTE 1 At 80 MHz end 800 MHz. the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
Field strengths from fixed transmitters, such as base stations for radio(cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured eld strength in the location in which the PT3 device is used exceeds the applicable RF compliance level above, the should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the PT3.
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than [Vi] V/m.
Recommended separation distances between portable and mobile RF communications equipment and the PT3 device.
PT3 device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the PT3 device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the PT3 as recommended below, according to the maximum output power of the communications equipment.
Rated maximum output power of transmitter W
Separation distance according to frequency of transmitter m
Electrostatic discharge(ESD) lEC61000-4-2
150kHz to 80MHz d=1.2 √p
80MHz to 800MHz d=1.2 √p
800MHz to 2,5GHz d=2.3 √p
0.01
0.12
0.12
0.23
0.1
0.38
0.38
0.73
1
1.2
1.2
2.3
10
7.8
7.8
3.3
100
12
12
23
For transmitters rated at a maximum output power not listed above, recommended separation distance d in meters(m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts(W) accordable to the transmitter manufacturer. NOTE 1 At 80 MHz and 800 MHz the separation distance for the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
WARRANTY
Please contact your dealer or the device center in case of a claim under the warranty. If you have to send in the unit, enclose a copy of your receipt with clear statement of defect description.
The warranty terms as below:
The warranty period for device is one year from date of delivery. In case of a warranty claim, the date of delivery has to be proven by means of the sales receipt or invoice.
Repairs under warranty do not extend the warranty period.
The following cases are excluded under the warranty
All damage which has arisen due to improper treatment, e.g. nonobservance of the user instruction.
All damage which is due to repairs or tampering by the customer or unauthorized third parities.
Damage which has arisen during transport from the manufacturer to the consumer or during transport to the service centre.
Accessories which are subject to normal wear and tear.
Liability for direct or indirect consequential losses caused by the unit is excluded even if the damage to the unit is accepted as a warranty claim.
Manufactured for iHealth Labs, Inc. USA: iHealth Labs, Inc. www.ihealthlabs.com 120 San Lucar Ct., Sunnyvale, CA 94086, USA +1-855-816-7705 Europe: iHealthLabs Europe SAS www.ihealthlabs.eu 36 rue de Ponthieu, 75008, Paris, France iHealthLabs Europe SAS www.ihealthlabs.eu 36 rue de Ponthieu, 75008, Paris, France Famidoc Technology Co., Ltd. No. 212 Yilong Road, Hexi Industrial Zone, Jinxia, Changan Town, Dongguan 523853, Guangdong Province, China
Need help?
Do you have a question about the PT3 and is the answer not in the manual?
Questions and answers