Comfort Zone CZ220 Series Owner's Manual

Comfort Zone CZ220 Series Owner's Manual

Ceiling mounted heater

Advertisement

CZ220 Series
Ceiling Mounted Heater
HARDWIRED INSTALLATION REQUIRED
This heater must be grounded and hardwired to a properly
sized current protection circuit breaker in accordance with
the (US) National Electric Code and local codes.
Description
• Adjustable Heat Settings
• Fan-Forced for Wide Heat Circulation
• Horizontal and Vertical Air Flow with Tilt Feature
• Sturdy Heavy Gauge Steel Body
• High Limit Thermal Cut-Out Switch
Save These Instructions
www.comfortzoneproducts.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CZ220 Series and is the answer not in the manual?

Questions and answers

gary
April 1, 2025

need to replace fan motor

Summary of Contents for Comfort Zone CZ220 Series

  • Page 1 CZ220 Series Ceiling Mounted Heater HARDWIRED INSTALLATION REQUIRED This heater must be grounded and hardwired to a properly sized current protection circuit breaker in accordance with the (US) National Electric Code and local codes. Description • Adjustable Heat Settings • Fan-Forced for Wide Heat Circulation •...
  • Page 2: General Safety Information

    This is a precaution to prevent serious shock. visual imperfections. For repairs covered under warranty, see warranty 7. This heater is not suitable for use in hazardous locations as defined statement. For all other repairs contact Comfort Zone Customer ®...
  • Page 3: Specifications

    SPECIFICATIONS: CZ220 SERIES HEAVY DUTY 5,000W ELECTRIC UTILITY HEATER WATTS SWITCH POSITION VOLTS (VAC) PHASE AMPS BTU/HOUR 5,000W 208-240V, 60Hz 20.9 17,060 4,000W 208-240V, 60Hz 16.7 13,650 3,000W 208-240V, 60Hz 12.5 10,240 FAN ONLY AIR THROW HORIZONTAL 18 FT (APPROXIMATE)
  • Page 4: Operation

    www.comfortzoneproducts.com OPERATION INSTALLING THE HEATER: LOCATING THE HEATER: SERIES MODEL: CZ220 Install the heater out of traffic areas, maintaining the clearances stated in Figure 1 above. The air flow from the heater must not HEAVY DUTY 5,000W be restricted or obstructed by any items in the room. When ELECTRIC UTILITY HEATER more than one heater is used in an area, the heaters should be arranged so that the air discharge of each heater supports the...
  • Page 5 www.comfortzoneproducts.com CONDUIT CONDUIT CONNECTOR 3ft. If Heater is to min. be turned CEILING JOIST and wire is inside conduit. WASHER FLEXIBLE FLEXIBLE CONDUIT CONDUIT CONNECTOR BRACKET If Heater is to be connected 3/8" DIAMETER with NM Cable. LAG BOLT Figure 4b: Double-Screw Mounting, For Fixed Position FLEXIBLE FLEXIBLE NM CABLE NM CABLE...
  • Page 6: Safety Instructions

    www.comfortzoneproducts.com LIMITED WARRANTY ADJUSTING AIR FLOW: 1. Swivel the unit- If mounted on a single center lag bolt Figure This unit is guaranteed to the original retail purchaser against 4a, turn the entire heater and bracket assembly left or right. defects in quality or workmanship for a period of one year 2.

Table of Contents

Save PDF