Summary of Contents for Comfort Zone CZ260ER Series
Page 1
CZ260ER Series *Model CZ260ER2C has 2 remote controls Digital Ceiling Mounted Heater HARDWIRED INSTALLATION REQUIRED This heater must be grounded and hardwired to a properly sized current protection circuit breaker in accordance with the (US) National Electric Code and local codes.
This is a precaution to prevent serious shock. visual imperfections. For repairs covered under warranty, see warranty 7. This heater is not suitable for use in hazardous locations as defined statement. For all other repairs contact Comfort Zone Customer ®...
SPECIFICATIONS: CZ260ER SERIES DIGITAL HEAVY DUTY 10,000W ELECTRIC UTILITY HEATER WATTS SWITCH POSITION VOLTS (VAC) PHASE AMPS BTU/HOUR 10,000W HIGH (Default) 208-240V, 60Hz 41.7 34,120 MEDIUM FAN ONLY AIR THROW HORIZONTAL 18 FT (APPROXIMATE) RECOMMENDED CIRCUIT BREAKER 60 AMP or larger, in accordance with NEC and local codes.
5 seconds to accept the setting. Once the display stops flashing, the room temperature will reappear on the LED screen to indicate the desired temperature is set. BRACKET INSTALLATION FOR CZ260ER SERIES In any temperature mode, the unit will stay in that mode, Refer to Figure 4.
Page 5
www.comfortzoneproducts.com CONNECTING THE POWER: 1. With the power off at the breaker, remove all screws from the bottom lid for access to the electrical section of the heater. 2. Attach flexible cable through a knock-out in the side of the CEILING JOIST heater following NEC and local codes, (See Figure 6) and SPECIFICATIONS for recommended wiring and circuit...
www.comfortzoneproducts.com CARE AND MAINTENANCE: CLEANING THE HEATER: 1. Do not disassemble the heater to clean it. 2. The heater should be powered OFF and disconnected from the power at the circuit breaker before attempting to clean any portion of the heater. 3.
www.comfortzoneproducts.com LIMITED WARRANTY This unit is guaranteed to the original retail purchaser against defects in quality or workmanship for a period of one year from the date of original purchase. If this unit fails because of a manufacturing defect within 30 days of purchase, return the unit, with your receipt, to the retailer.
Page 8
www.comfortzoneproducts.com ERROR CODE TROUBLESHOOTING GUIDE: Error Code Possible Cause Recommended Solution Clearing Error Codes E1 (Fan Insufficient Clearance Around Ensure Heater is Installed with Sufficient Clearance All-Around, See Figure 1. To Clear E1 Code: Heater *6 feet minimum mounting from floor Blade Not 1.
Need help?
Do you have a question about the CZ260ER Series and is the answer not in the manual?
Questions and answers