LDU ERROR CODES
B
LDU Error Code
TRACTION
FAULT 5502
STEERING
FAULT 5502
3WD TRACTION
FAULT 5502
STEERING
FAULT 5503
3WD TRACTION
FAULT 5503
TRACTION
FAULT 5504
3WD TRACTION
FAULT 5504
STEERING
FAULT 5504
TRACTION
FAULT 5505
3WD TRACTION
FAULT 5505
STEERING
FAULT 5505
STEERING
FAULT 5506
en-104
Description
High Side Output Low:
The system detected that the high
side output is low. This indicates that
the high side input has a short circuit
to B-.
High Side Output High When Off:
The system detected the the high
side output is high. This indicates
that the high side has a short circuit
to B+.
High Side Overload:
The system has detected high
continuous current on high side out.
High Side Out Not Connected:
Detected that nothing has been
connected to the high side output.
High Side High Peak Current:
The system has detected high peak
current on high side out.
High Side Switch Short Circuit
Supervision:
A short circuit of the high side
controlled by the supervision CPU
has been detected. This indicates a
hardware failure.
High Side Switch Short Circuit Main:
A short circuit of the high side
controlled by the main CPU has
been detected. This indicates a
hardware failure.
Safety, Operation, & Maintenance Manual
Alarm
Caution
Engine
Sound-
LED
Stop
ing
On
Off
Yes No
Yes No
Traction
Mow Stop
Stop
Yes No
Yes No
Lithium

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

10029194

Table of Contents