Step G - Sanitize, Test and Purge System
PRESSURETESTTHESYSTEM
NOTE:Completethesanitizingproceduresonthe
precedingpagebeforepressuretesting.
To pressure test the system, complete the following
steps.
1. Open the water supply valve to the Reverse
Osmosis system.
2. Purge air from the house plumbing by opening sev-
eral house faucets. Close faucets when water runs
smooth, with no spurting.
3. Pressure will start to build in the RO system. In
about 2 hours check all fittings and connections.
Check for water leaks. Fix leaks if any are found. If
problems exist, refer to the troubleshooting chart or
call the toll free number below).
NOTE:Whenthesystemisfirstpressurized,water
may''spurt''fromthefaucetairgapholeuntilairis
expelledfromtheROsystem.
Pleasereviewthefollowingoperatingfeatures
beforeusingyourReverseOsmosissystem:
You will not have filtered water immediately. It may
take several hours to fill the storage tank and create
maximum flow from the Reverse Osmosis faucet.
Water Pressure from the Reverse Osmosis faucet will
be less than your standard faucet.
Water will run to the drain while the Reverse
Osmosis system is producing water, even if you are
not drawing water from the Reverse Osmosis faucet.
You may hear a small quantity of water going to the
drain at times when water is not being used. This is
normal. Water going to the drain will automatically
shut off when the storage tank is full.
PURGINGTHESYSTEM
To purge the system, complete the following steps.
1. Open the Reverse Osmosis Faucet and let water
flow through the system for a 24 hour period. Water
flow will be a slow trickle at this time.
NOTE:DonotconsumewaterfromtheROsys-
temuntilpurgingiscomplete.
2. Close the Reverse Osmosis faucet after the 24 hour
purging period is complete.
3. When the purging is finished, your Reverse
Osmosis system is ready for use.
Kitchen
Faucet
Storage
Tank
Water Supply Shutoff
Valve to Reverse
Osmosis System
NOTE:CodesinthestateofMassachusettsrequire
installationbyalicensedplumberanddonotper-
mittheuseofsaddlevalves.
IfyouliveinthestateofMassachusetts,review
plumbingcode248-CMRoftheCommonwealthof
Massachusettsbeforeproceedingwiththeinstalla-
tion.
NOTE:Aswithallotherwatersystemapplications,
leaksmayoccur.Becausethesystempressure
buildsslowly,leaksmaynotbeimmediatelyappar-
ent.Recheckforleaks24hoursafterpurgingthe
systemiscomplete.