Download Print this page
Sealey EWP40 Instructions
Sealey EWP40 Instructions

Sealey EWP40 Instructions

Electrical water pump

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE OR PERSONAL INJURY, AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1.
SAFETY INSTRUCTIONS
WARNING! THIS PUMP MUST BE INSTALLED AND TESTED BY A QUALIFIED ELECTRICIAN. See installation.
Once installed, the following tests and checks must be regularly undertaken:
p
1.1.
ELECTRICAL SAFETY. p WARNING! It is the user’s responsibility to read, understand and comply with the following:
You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads, plugs and
all electrical connections for wear and damage. You must ensure the risk of electric shock is minimised by the installation of appropriate safety
devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution board. We also recommend that an RCD
(Residual Current Device) is used with all electrical products. It is particularly important to use an RCD together with portable products that are
plugged into an electrical supply not protected by an RCCB. If in doubt consult a professional electrician. You may obtain a Residual Current
Device by contacting your Sealey dealer. You must also read and understand the following instructions concerning electrical safety.
1.1.1. The Electricity At Work Act 1989 requires all portable electrical appliances, if used on a business premises, to be tested by
a qualified Electrician at least once a year by using a Portable Appliance Tester (PAT).
1.1.2. The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of the appliance,
and the safety of the appliance operator. If in any doubt about electrical safety, contact a qualified electrician.
1.1.3. Ensure the insulation on all cables and the product itself is safe before connecting to the mains power supply.
1.1.4. Ensure that cables are always protected against short circuit and overload.
1.1.5.
Regularly inspect power supply, leads, plugs and all electrical connections for wear and damage,
especially power connections, to ensure that none are loose.
1.1.6. Important: Ensure the voltage marked on the product is the same as the electrical power supply
to be used, and check that plugs are fitted with the correct capacity fuse. A 13Amp plug may require
a fuse smaller than 13Amps for certain products (subject to 1.1.10. below) see fuse rating at right.
1.1.7. DO NOT pull or carry the powered appliance by its power supply lead.
1.1.8. DO NOT pull power plugs from sockets by the power cable.
1.1.9. DO NOT use worn or damaged leads, plugs or connections. Immediately replace or have repaired by
a qualified Electrician. A U.K. 3 pin plug with ASTA/BS approval is fitted. In case of damage, cut off
and fit a new plug according to the following instructions (discard old plug safely).
(UK only - see diagram at right). Ensure the unit is correctly earthed via a three-pin plug.
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
After wiring, check there are no bare wires, that all wires have been correctly connected and that the wire restraint is tight.
1.1.10. Extension cable use. Only use a cable designed for use with water equipment. Contact your dealer or a qualified electrician for
advice. Ensure water is kept clear of electrical mains power supply. DO NOT touch switch or plug with wet hands.
1.2
GENERAL SAFETY
WARNING! Pump must be used in accordance with Health & Safety, government, local authority, and water authority rules and regulations.
Familiarise yourself with application and limitations, as well as the specific potential hazards peculiar to the pump.
p
WARNING! Disconnect the pump from the mains power before servicing or performing any maintenance.
3
Maintain the pump in good condition (use an authorised service agent). Keep the pump clean.
p
Replace or repair damaged parts. Use genuine parts only. Non authorised parts may be dangerous and will invalidate the warranty.
3
Locate pump in an adequate working area for its function, keep area clean, tidy and free from unrelated materials.
3
Only use for pumping clean cold or warm water, (NOT exceeding 35
3
If used In situations of possible flooding, user is responsible for installing appropriate back up procedures, alarms etc in case of pump failure.
3
If used with swimming pools, fish ponds, etc, ensure areas are clear of people and animals. (including removal of fish from ponds). Note: this
3
pump is not designed for continues use in a fish pond or similar water feature or display.
3
DO NOT operate the pump if any parts are damaged or missing as this may cause failure or possible personal injury.
DO NOT use the pump for any purpose other than for which it is designed.
8
DO NOT use to pump chemicals, fuels, fatty liquids or salt water.
8
DO NOT pump sludge, sand, gravel, mud, or fibrous materials. Ensure the inlet hose will not pick up any solid materials. Sand and
8
such substances will reduce working life of pump, and invalidate your warranty.
8
DO NOT use to pump septic tanks or settling pits.
DO NOT submerged the pump or any electrical cable in water. Protect the pump form external wet conditions.
8
DO NOT operate pump during freezing temperatures. DO NOT allow any part of the pump or pipes to freeze.
8
DO NOT carry pump by its electrical cable, or piping. The pump should be secured in its operating location.
8
When not in use switch pump off, remove plug from power supply and drain out any water.
8
WARNING! DO NOT allow uncontrolled discharge of contaminated water thus polluting environment.
3
p
2.
INTRODUCTION & SPECIFICATIONS
The EWP40 is designed for pumping clean cold or warm water, (NOT exceeding 35
for filling tanks, wells, large ponds, swimming pools, irrigation and the general transfer of water. The pump may also be used to circulate water.
Model
Power
EWP40
500W
Max head
Max flow
Performance example
head(m) @ Flow l/m
37m
40 l/m
INSTRUCTIONS FOR:
ELECTRICAL WATER PUMP
Model: EWP40
C).
O
C) to supply domestic, agricultural or light industrial use. Typical use would be
O
@ 10m = 30 l/m
@ 28m = 10 l/m
Yellow & Green
Earth wire
Blue
Neutra
l
FUSE RATING
5 Amp FUSE
Outlet pipe
Length x width x height
bore
1”
390 x 190 x 260mm
Brown
Live
wire
wire
restrai
EWP40 - 1099 - (1) - 070800

Advertisement

loading

Summary of Contents for Sealey EWP40

  • Page 1 ELECTRICAL WATER PUMP Model: EWP40 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
  • Page 2 If pump becomes blocked, remove the inlet pipe and direct jet of water through the outlet whilst running the motor for several seconds. Repeat this operation until the blockage has been expelled. If this action does not remedy the problem contact your local Sealey service agent.