HP 5305 B Operating And Service Manual page 13

1300 mhz counter
Table of Contents

Advertisement

1. Apply input power to 5300 ac receptacle.
2. Turn counter on with 5300 SAMPLE RATE control.
3. Set RANGE switch to CHK position. Display is a
Resolution
Selector
Display
10 kHz
0010.00
1 kHz
010.000
100 Hz
10.0000
10 Hz
0.00000
1 Hz
●000.000
.1 Hz
●00.0000
●Indicates overflow light is on.
Figure 9E-3-3. Self-Check Measurements
Adjust SAMPLE RATE for minimum display time
(full ccw).
function of RESOLUTION switch.
5300A Self Check
Annunciator
M, Hz
M, Hz
M, Hz, C
M, Hz, C
K, Hz, C
K, Hz, C
5300B Self Check
Display
Annunciator
000010.00±1
00010.000±1
0010.0000±1
010.00000±1
10000.000±1
0000.0000±1
Model 5305B
Operation
M, Hz
M, Hz
M, Hz, C
M, Hz, C
K, Hz, C
K, Hz, C
9E-3-3

Advertisement

Table of Contents
loading

Table of Contents