Page 1
Assembly Instructions MODEL: GRANGE - 7 PRODUCT SIZE(L x W x H): PLEASE REFER TO PACKING LIST BELOW PLEASE READ CAREFULLY BEFORE ASSEMBLY Item No. & Packing List Packing List Product Size (LxWxH) AL No.1 AL No.2 AL No.3 AL No.4 AL No.5 AL No.6 PC No.1...
Page 2
Assembly and Maintenance Advice 1. For safety purposes, we strongly recommend that the product will be assembled by at least two people. 2. Some parts have sharp edges. Please be careful when handling components. Always wear gloves, shoes and safety goggles during assembly. 3.
Page 3
4. The unique design allows the greenhouse to be easily extended at any stage in 4m long sections as detailed in the table of Front Page. 5. A steel base is not required as the aluminium base frame is fixed to the necessary concrete footings with the expansion bolts provided, alternatively you can easily secure it to a timber base with timber screws (not provided).
Page 4
POLYCARBONATE ORIENTATION PLEASE NOTE: We have recently changed our polycarbonate film. All panels must be installed with the white film facing inside and the clear film with writing facing the sun. If you have any questions please feel free to contact us.
Page 14
PART PART PART PART QTY. QTY. QTY. QTY. L15A L02A L02B L02W L02H M6X12 L02K M6X20 L03A L03B Ø4X16D L04B Ø5X30 L04E Ø4X10 L05B L05C M8X60 L05D W 08 W08A 4 M5X35 Ext.-4 Section Assembly L08E Overview L05D L02B L05D L04B L02W L02W...
Page 15
Expansion screw/Concrete ground * It is crucial the a + b dimensions are the same to ensure the base is square. Support at corners only is not adequate.
Page 16
Grange-7 (4 x 7M) Front Assembly Back Assembly 43.4mm Item No. 4 x 7M 8 x 7M 12 x 7M 20 x 7M 16 x 7M Dimensions 7063.8 7063.8 7063.8 7063.8 (mm) 7063.8 (mm) 4059.8 8063.8 12067.8 20075.8 16071.8 (mm) 8147.3...
Page 17
Grange-7 + Ext.-4 Section Assembly (8 x 7M) Front Assembly Back Assembly Grange-7 + Ext.-4 Section Assembly * The basic model, Grange-7, can be easily extended by adding a 'Ext.-4 Section Assembly' each time for a longer size.
Page 18
Front Back Ext.-4 Section Assembly Grange-7 * This shows a layout for W05's positions where it is placed in the middle of PC panel for each section.
Page 27
L03B L02K L03B L02H L02H Please ensure L02H and L02K profiles are installed back to back and bolted together as shown below on Fig.3 & 4. L03B L02K L02K L02H L02H ∅ Drill 2 holes, 7, through each L02H & L02K profiles as shown on Fig.
Page 32
L04E L04D L04D L04E L04E L04E L04E L04D L04E L04D Slide 2 x S01 into each L04D & E, and put each profile onto the edge of each PC panel, then tighten all profiles at each end with S01. L04D&E S01x2pcs L04E L04E...
Page 37
Roof Vent Assembly Roof Vent Assembly * The roof vents should be lifted through the vent opening from the inside of the greenhouse, then lowered into position from above the greenhouse. So the holes of the L15A line up L15A with the ridge holes.
Page 38
Insert all Y6 panels into each side of greenhouse. Note: If it is difficult sliding any panels in the channels, using soapy water or olive oil in the channels can reduce the friction. Insert all Y7 panels into each roof of greenhouse.
Page 39
L04B L04B L04B L04B L04B L04B L04B Pay attention to the cut edge of L04B which should be fixed, facing up. L04B L04B S01x2pcs Once the L04B is in place. S01x6pcs Pay attention to the cut edge of L04B A small bead of silicon suitable which should be fixed, facing down.
Page 40
L05D L05D L05D L05D Insert all Y9 panels into each roof of greenhouse. Note: If it is difficult sliding any panels in the channels, using soapy water or olive oil in the channels can reduce the friction.
Page 41
L04E L04E L04E L04E L04E L04E L04E L04E Once the L04E is in place. A small bead of silicon suitable for polycarbonate can assist in preventing leaks. L04E Insert all Y7 panels into each roof of greenhouse. Note: If it is difficult sliding any panels in the channels, using soapy water or olive oil in the channels can reduce the friction.
Page 42
Door2 Assembly Door1 Assembly Door3 Assembly Use L09 to cover the edges of all Y7 after all roof PC panels are fixed in place, then tighten them with Z03. When installing the J06 and the second section of gutter, it can help if you have 2 people, one guiding the gutter into the J06 and the other gently tapping the end of the gutter with a rubber mallet.
Page 43
J02R/L J02R/L J02R/L J02R/L To avoid leaking, using silicone on J02R / L, T08 and J07 is an option (see Fig. below). J02R/L Drill one hole on both L01A approx 500mm up from the bottom, Dia. 2.5mm, then tighten J08 with Z02, and push T08 into the channel of J08 (see Fig.
Page 44
Once the L09 is in place. A small bead of silicon suitable for polycarbonate can assist in preventing leaks. Z04&S04 L04D Z04&S04 L04D Drill the holes on each L04D as shown, Dia.3.2mm, and secure the hooks W10 with Z04 & S04, then ensure W01 works with Door1 &...
Need help?
Do you have a question about the GRANGE-7 and is the answer not in the manual?
Questions and answers