SAFETY PRECAUTIONS Basic safety precautions must be followed when handling or using electrical products, especially those within the reach of children. Please make yourself aware of the following guidelines: This product should only be used by children who are 8 years and older or by persons with disabilities who have received supervision and instructions on the safe use and the hazards involved when using this product.
Page 3
• WARNING Please do not touch electrical outlet with wet hands. • may cause electric shock Please do not pour liquids such as water or detergent on electronic outlet and the toilet. • may cause fire, electric shock, heat or short circuit •...
Page 4
WARNING • Or it may cause fire, electric shock, heat, and short circuit because of moisture condensation Please do not damage the power cable or plug. Do not strike, yank, twist, bend excessively, or alter the electrical cords. Also, do not place anything heavy bind or pinch the cords •...
Page 5
The product must be connected to the cold water supply • Or it may cause body burn or machine fault Please confirm if the electrical outlet is connected to the ground. • Or it may cause electric shock because of fault or short circuit. The outlet for power wire should obey the following rules or it may cause fire or electric shock.
LINE DRAWINGS Remote Control Spray/Heat Level Display eFoam Stop Rear Wash User 1 Settings User 2 Night Light Temperature Spray/Heat Adjustment Adjustment Feminine/Front Wash Spray Wand Adjustment Raise/Lower Seat and Lid Raise/Lower Lid Flush Fresh Water Reset...
Page 8
FEATURES Feature Description Rear Wash Provides cleansing on the back part Feminine Wash Provides cleansing on the front or feminine area SPA Function Provides a soothing pulsating effect whenever desired Auto Flush Automatically flushes after every use Bowl Pre-Rinse Automatically cleanses the bowl before every use SyphonAssist Flush Uses a strong syphoning action to flush dirt away Battery Backup Flush...
OPERATION Stop When the power is off, long press it for more than 2 seconds to turn the power on. When the power is on, long press it for more than 2 seconds to turn the power off. ...
Page 10
Press the > button to increase the water temperature. Press the < button to decrease the water temperature. Press this button to go to the mode of seat temperature adjustment. Press the > button to increase the seat temperature. ...
Page 11
the user is seated. The water temperature starts changing from low to high. The corresponding relationships between the gear position of strong & weak massage and water pressure are as follows: Water Pressure: Close, Low Cool & Warm Massage: Low Water Pressure: Mid Cool &...
Page 12
Factory Settings: On Press and hold the [Setting] button, then press the [Cover Flip] button to turn the automatic cover flip function on/off. It will not open the cover automatically when you are close to it if the automatic cover flip function is off (it will give a short beep instead).
Page 13
Press and hold the [Setting] button, then press the [Gear Position +] or [Gear Position -] button to set the sensing distance. Press the < [Gear Position -] button to decrease the sensing distance. Press the > [Gear Position +] button to increase the sensing distance. ...
Page 14
Adjusting The Flush Time Press and hold the side Feminine Wash button for 8 seconds to enter into the Flush Time Adjustment function and adjust the pulse valve time. The first step: The green light flashes (0.5s dark 0.5s bright) during the pulse valve 1’s flushing time adjustment.
TROUBLESHOOTING GUIDE Power Switch Fault Failure Analysis Solutions Check whether the socket is electrified or not and the plug if Check circuit loosened or not Check whether the toilet is turned Press the power on/off button until on or not (if the side button is on or the side button’s light is on not) Product Not...
Page 16
Dryer/Fan/Seat Temperature Fault Failure Analysis Solutions Drying with Check the fan temperature Adjust the fan temperature setting if it’s off or low cold air according to the manual Seat is not Check the seat temperature Adjust the seat temperature setting if it’s off or low warm enough according to the manual Remote Failure...
Common Problems Fault Failure Analysis Solutions Check if the water source is Open the water source open or not Check if the water supply Open the water supply angle angle valve is open or not valve No water Check if the water supply angle valve filter net is Clean the filter net blocked or not...
CLEAN AND CARE Note: Turn off the power, close the water supply angle valve, and stop the water supply before doing any maintenance work. DO NOT rinse this product with water during maintenance.
Page 19
Toilet Bowl Cleaning Please ensure that the electrical plug is taken out. Please use soft damp cloth to wipe the toilet shelf and seat. The dirt should be easily removed. it's not, you neutral detergent...
Page 20
Self-Cleaning Nozzle Maintenance Wash the cleaning tube and nozzle with a toothbrush coated with toothpaste. Do not use excessive force. Press the side [Stop] button to take the nozzle tube back once you’re done cleaning. Cleaning The Junction Block ...
water quality. When the cleaning strength becomes weaker, clean the steel mesh or replace the filter on time. Close the water supply angle valve when disassembling the filter. Tighten the filter during installation to avoid water leakage. Turn the filter counterclockwise with a coin to open the filter. It is recommended to clean the steel mesh every 1-2 months.
PRODUCT SPECIFICATIONS Rated Voltage 120V~, 60Hz Rated Power 1150W Power Cable 1.5m Applicable Water 40 – 90 PSI Pressure Water Temperature 39.2 to 95 Ambient Temperature 39.2 to 104 Net Weight 99.2 lbs Waterproof Level IPX4 0.13 – 0.19 gpm (0.5 – 0.7L/min) Cleaning Water Flow Seat Temperature Total 4 gears (Normal: around 104...