Advertisement

Quick Links

ABOUT US
Driven by the passion for innovation, we at Dr Trust endeavour to provide our
customers with the latest medical inventions with an objective to promote good
health and wellness all around the world. All the medical devices and health
monitors provided by Dr Trust are supported by accurate, latest and ground
breaking technologies, innovated at our headquarter in NY, USA. All our
products adhere to the most stringent CE and FDA guidelines and are strongly
recommended by doctors and health practitioners. Our products are designed
in the utmost exemplary ways to ensure that their accuracy and convenience
are unrivalled. The ease of their use and operation makes them even more
suitable for users of all age groups.
Dr Trust strives to enhance the quality of lifestyle by providing with the most
trusted and innovative health care and wellness products. Being a renowned
global leader in health care products, Dr Trust ensures that our technically
efficient team works dynamically and tirelessly to provide the best of the
medical devices to our clients. The products that we have to offer are suitably
designed for use at homes, laboratories and hospitals.
Our ground breaking solutions allow you to monitor your health in the easiest
ways possible. In today's era when all of our lives are too hassled to handle, it
becomes a bit difficult to pay attention to our health. But it has now become
easier with the coming of the monitoring devices which can be conveniently
used at homes and even on the go.
We bring to you a variety of best self medical devices, trusted and used by
Doctors, medical professionals and home users all over the world.
10
33
Dr Trust 
AFIB Pro Blood Pressure Monitor 102
QUICK START GUIDE
Step 1
Check batteries and insert the air tube
from the cuff into the air jack.
Step 3
Slide the blood pressure cuff onto your
upper arm and secure it so that it sits
snugly about one inch above of your
elbow.
Step 5
The device is intended for taking 2
measurements in succession in AF
mode. Your result is calculated and
d i s p l aye d a s a s i n g l e ave rage d
measurement on the display screen
with Atrial Fibrillation detector icon (if
atrial fibrillation is detected).
10
Step 2
Before starting the measurement,
select the measuring mode: Standard
Single or AFIB Mode and make
settings for user no, time, and date etc.
Step 4
Simply push the power button and cuff
begins to inflate with controlling
deflation speed automatically.
Step 6
In Standard mode, you will get the
pressure value when the pump stops
a f t e r rea c h i n g t o t h e i n f l at i o n
pressure.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AFIB Pro and is the answer not in the manual?

Questions and answers

Summary of Contents for Dr. Trust AFIB Pro

  • Page 1 ABOUT US Dr Trust  AFIB Pro Blood Pressure Monitor 102 Driven by the passion for innovation, we at Dr Trust endeavour to provide our customers with the latest medical inventions with an objective to promote good QUICK START GUIDE health and wellness all around the world. All the medical devices and health monitors provided by Dr Trust are supported by accurate, latest and ground breaking technologies, innovated at our headquarter in NY, USA.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. INTRODUCTION 7. CARE AND MAINTENANCE, RECALIBRATION 1.1. Features of AFIB Pro 8. SAFETY, CARE AND DISPOSAL 1.2. Key Components 1.3. Important Information about Self-Measurement 9. REFERENCE TO STANDARDS 2. IMPORTANT INFORMATION ON THE SUBJECT OF 10. TECHNICAL SPECIFICATIONS BLOOD-PRESSURE AND ITS MEASUREMENT 2.1.
  • Page 3: Introduction

    1. INTRODUCTION 1.1. Features of AFIB Pro 1.2. Key Components Dr Trust AFIB Pro Blood Pressure Monitor -102 comes with integrated The various components of AFIB Pro -102 time/date display. It is a fully automatic, digital blood-pressure measuring device for use on the arm, which enables very fast and reliable measurement of the systolic and diastolic blood-pressure as well as the pulse frequency by way of the oscillometric method of measurement.
  • Page 4: Important Information On The Subject Of Blood-Pressure And Its Measurement

    2. IMPORTANT INFORMATION ON THE SUBJECT OF BLOOD-PRESSURE AND ITS MEASUREMENT · The application of the cuff and its pressurization on any limb where 2.1. How does High/Low Blood-Pressure arise? intravascular access or therapy, or an arteriovenous (A-V) shunt, is present As your heart beats, it pumps your blood round your body so that your muscles because of temporary interference to blood flow and could result in injury to can get all the energy and oxygen they need.
  • Page 5: Operation

    2.5. How does Dr Trust AFIB Pro 102 can help controlling AFIB? and 120 and 80 Dr Trust AFIB Pro Blood Pressure Monitor 120 provides a convenient way to screen for AFIB. Knowing your blood pressure and knowing whether you have Normal...
  • Page 6: Setting Date/Time

    Ÿ Unit setting- the unit “ Kpa “ or “ mmH “ flashes on the display : Choose the 3.2. Setting date/time desired Unit with “ “ button and confirm with “ “ (ON/OFF) button. How to enter into the setting mode Ÿ...
  • Page 7: Common Sources Of Error

    4.2. Common sources of error c) Lay the arm on a table, with the palm upwards. Support the arm a little with a rest (cushion), so that the cuff rests at Note: Comparable blood-pressure measurements require the same conditions! about the same height as the heart. Take These are always quiet conditions.
  • Page 8 In AF Mode Measured result In AF mode, 2 measurements are automatically taken Example 1. in succession and the result is then automatically The measured systolic and diastolic blood-pressure analyzed and displayed. Because blood pressure values as well as the pulse are now displayed. constantly fluctuates, a result determined in this way Example (Fig.): is more reliable than one produced by a single...
  • Page 9: Discontinuing A Measurement

    Example (Fig.): Systole 128, Diastole 70, Pulse 80 4.7. Memory – cancellation of all measurements The measurement results are displayed until you Before you delete all readings stored in the memory, make sure you need not switch the device off. If no button is pressed for 3 refer the readings at a later date.
  • Page 10: Error Messages/Malfunctions

    6. ERROR MESSAGES/MALFUNCTIONS The device frequently fails to 1. Check the positioning of the cuff. If an error occurs during a measurement, the measurement measure the blood pressure values, 2. Measure the blood-pressure again in is discontinued and a corresponding error code is displayed or the values measured are too low peace and quiet under observance of the (Example: Error No.
  • Page 11: Care And Maintenance, Recalibration

    8. SAFETY, CARE AND DISPOSAL The manufacture of the devices takes place according to the terms of the Safety and protection European standard for blood-pressure measuring devices (see technical data) You must consult your specialist dealer or chemist if there are technical This instrument may be used only for the purpose described in this booklet.
  • Page 12: Reference To Standards

    9. REFERENCE TO STANDARDS Measuring range Pressure: 30 to 280 mmHg (in 1 mmHg Device Standard: Device corresponds to the requirements of the European increment) standard for Pulse: 40 to 199 beat/minute Standard Static accuracy Pressure: ±3mmHg / Pulse: ±5% of reading IEC60601-1-6:2010+A1:2013/ EN60601-1-6:2010+A1:2015 Measuring resolution 1mmHg...
  • Page 13: Manufacturer's Declaration

    Electromagnetic Immunity test test level level environment -guidance Dr Trust AFIB Pro Blood Pressure Monitor 102 is intended for use in the electromagnetic environment specified below. The customer or the user of Afib Electrostatic ±6 kV contact ±6 kV contact Floors should be wood, Pro should assure that it is used in such an environment.
  • Page 14 Surge IEC ±1 kV differential Not applicable Mains power quality part of Dr Trust AFIB Pro Blood 61000-4-5 mode should be that of a Pressure Monitor 102, including ±2 kV common...
  • Page 15 RF disturbances are controlled. propagation is affected by absorption and reflection from structures, The customer or the user of Dr Trust AFIB Pro Blood Pressure Monitor 102 can objects, and people. help prevent electromagnetic interference by maintaining a minimum distance...
  • Page 16: Customer Support

    CUSTOMER SUPPORT CONTACT ADDRESS For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be determined using the Nureca INC.USA equation applicable to the frequency of the transmitter, where P is the maximum 276 5th Avenue, Suite 704-397, output power rating of the transmitter in watts (W) according to the transmitter New York (NY) - 10001, USA...