Table of contents 1. Introduction 1.1. Features of theWrist Digital BP Monitor 1.2. Important information about self-measurement 2. Important information on the subject of blood-pressure and its measurement 2.1. How does high/low blood-pressure arise? 2.2. Which values are normal? 3. The various components of the blood-pressure monitor 4.
1. Introduction 1.1. Features of the Wrist Digital BP Monitor The blood-pressure monitor Wrist Digital BP Monitor (with integrated time/date display) is a fully automatic, digital blood-pressure measuring device for use on the wrist, which enables very fast and reliable measurement of the systolic and diastolic blood-pressure as well as the pulse frequency by way of the oscillometric method of measuring.
2. Important information on the subject of blood-pressure and its measurement 2.1. How does high/low blood-pressure arise? The level of blood-pressure is determined in a part of the brain, the so-called circulatory centre, and adapted to the respective situation by way of feedback via the nervous system. To adjust the blood-pressure, the strength and frequency of the heart (Pulse), as well as the width of circulatory blood vessels is altered.
Page 5
Table for classifying blood-pressure values (unit: mmHg) according to World Health Organization: Range Systolic Diastolic Measures Blood-pressure Blood-pressure Hypotension lower than 100 lower than 60 Consult your doctor Blood pressure optimum between 100 and 120 between 60 and 80 Self-check Blood pressure normal between 120 and 130 between 80 and 85...
4. Putting the blood-pressure monitor into operation 4.1. Inserting the batteries a) Insert the batteries (2 x size AAA 1.5V), thereby observing the indicated polarity. b) If the battery warning appears in the display, the batteries are empty and must be replaced by new ones.
Page 8
c) Click the MEMORY button to select User d) We suggest the first person to take their pressure to be User 1. Setting the time ,date This blood-pressure monitor incorporates an integrated clock with date display. This has the advantage, that at each measurement procedure, not only the blood-pressure values are stored, but also the exact moment of the measurement.
8) The corresponding hour can now be entered by pressing the MEMORY button. 9) Press the TIME button again. The last two characters (Minutes) now blink. 10) The exact time can now be entered by pressing the MEMORY button 11) How to select pressure unit , switchable of mmHg and kPa , Finished the whole setting process mentioned above , Press the TIME button again , Display “mmHg”...
influence the measurement result. Try and find time to relax by sitting in an armchair in a quite atmosphere for about ten minutes before the measurement. • Measure always on the same wrist (normally left). • Attempt to carry out the measurements regularly at the same time of day, since the blood-pressure changes during the course of the day.
5.4. Measuring procedure After the cuff has been appropriately positioned, the measurement can begin: a) Press the ON/OFF button, the pump begins to inflate the cuff. In the display, the increasing cuff-pressure is continually displayed. b) After reaching the inflation pressure, the pump stops and the pressure slowly falls away.
5.7.Novel features : Positioning Detection / movement detection in the measuring How to select Positioning detection mode : To press and hold I/O button “ ” 3 seconds , then enter to Positioning selection mode Mode On2 is a default positioning detection mode . And to press “...
5.9. Memory– cancellation of all measurements Attention! Before you delete all readings stored in the memory, make sure you will not need refer to the readings at a later date. Keeping a written record is prudent and may provide additional information for your doctor’s visit. In order to delete all stored readings, depress the MEMORY button for at least 5 seconds, the display will show the symbol «...
normally and the values displayed are measurement. normal Please note: Blood pressure fluctuates continually so successive measurements will show some variability. Record the daily development of the values and consult your doctor. Please note: Blood pressure measured differs from Individuals visiting their doctor frequently those values measured by the doctor.
d) Do not drop the instrument or treat it roughly in any way. Avoid strong vibrations. e) Never open the device! Otherwise the manufacturer calibration becomes invalid! 8. Service life 5 years 9. Battery life : 300 times measurement with 2- size “AAA” alkaline Batteries 10.
A warning to remove primary batteries if the instruments is not likely to be used for some time Instrument care Clean the instrument only with a soft, dry cloth Disposal batteries and electronic instruments must be disposed of in accordance with the locally applicable regulations, not with domestics waste 11.
Page 18
Electrostatic ± 6 kV contact ± 6 kV contact Floors should be wood, concrete discharge ± 8 kV air ± 8 kV air or ceramic tile. If floors are (ESD) covered with synthetic material, 61000-4-2 the relative humidity should be at least 30 %.
Page 19
61000-4-3 GHz 80% AM (2Hz) d = 1.2×p 80Mhz to 800 MHz d = 2.3×p MHz to 2.5 GHz where P is the maximum output power rating of the transmitter in watts (W) according to he transmitter manufacturer and d is the recom- mended separation distance in meters (m).
Page 20
d = 1.2×p 0.01 0.12 0.12 0.23 0.38 0.38 0.73 For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can be determined using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
Page 21
Remark: Some electrical and electrical equipments forbid to abandon and disposal at will Manufacturer’s name and address Inapplicable baby Attention consult accompanying documents ingress of water IP22 TUV NO. Reading Instruction Book before use Type BF equipment For any query contact:- dr@drtrustusa.com...
Need help?
Do you have a question about the Wrist Digital Blood Pressure Monitor and is the answer not in the manual?
Questions and answers