Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear a face
instructions
shield
Place V block
correctly
1. SAFETY
Familiarise yourself with the applications, limitations and hazards of the press.
9
Maintain the press in good condition (use an authorised service agent).
9
Replace or repair damaged parts.
9
Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
Keep the press clean for best and safest performance.
9
Locate the press in a suitable work area, on a surface that is stable, level, dry, not slippery, and capable of sustaining the load.
9
Keep area clean and tidy and free from unrelated materials, and ensure there is adequate lighting.
9
WARNING! Always wear approved eye or face protection when operating the press.
Remove ill fitting clothing. Remove ties, watches, rings and other loose jewellery, and contain long hair.
9
Keep hands and body clear of the work table when operating the press.
9
Maintain correct balance and footing. DO NOT over reach. Ensure the floor is not slippery and wear non-slip shoes.
9
Keep children and unauthorised persons away from the working area.
9
DO NOT use the press for a task it is not designed to perform.
8
DO NOT adjust or tamper with the safety valve, or make any modifications to the press.
8
DO NOT exceed the rated capacity of the press. Avoid applying excessive force, use the pressure gauge to determine the applied
8
load.
DO NOT apply off-centre loads. Ensure that workpiece is centrally loaded and correctly secured before operating the press.
8
DO NOT allow the workpiece or the V blocks plates to fall from the press work bench.
8
DO NOT get the press wet or use in damp or wet locations or areas where there is condensation.
8
DO NOT operate the press when you are tired or under the influence of alcohol, drugs or intoxicating medication.
8
DO NOT climb upon the press.
8
DO NOT use if bent, broken, cracked, leaking or otherwise damaged, or if press has been subjected to a shock load.
8
DO NOT operate the press if any parts are missing as this may cause failure and/or possible personal injury.
8
DO NOT use the press to compress a spring or any other item that could disengage and cause a potential hazard.
8
DO NOT stand directly in front of loaded press and never leave loaded press unattended.
8
DO NOT allow untrained persons to operate the press.
8
DANGER! This model is purpose designed to withstand greater loads than the hydraulic unit can develop. For safety reasons, always
ensure the workpiece and press tools are secured on the table and will not flex or suddenly give way, causing danger to operator or
the workpiece.
WARNING! DO NOT use brake fluid, or any fluid other than a good quality jack oil, such as SEALEY HYDRAULIC JACK OIL, as
this may cause serious damage to the press and will invalidate the warranty.
When not in use, release pressure from the pump and clean the press. Stand or store the V blocks in a safe, childproof location.
9
WARNING! The warnings, cautions and instructions in this manual cannot cover all possible conditions and situations that
may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this
product, but must be applied by the operator.
2. INTRODUCTION
Heavy-duty steel frame construction with integral air motor powering hydraulic pump unit. Screw adjustable ram and adjustable work area
with removable tray. Sliding hydraulic ram assembly giving 280mm of lateral travel for off-centre pressing applications. Frame head fitted with
ram pressure gauge. Winch assisted press table adjustment. Storage for press pins included in frame. Supplied with press pins, flat pressing
plate/V-blocks.. 2 Year guarantee*. This item is heavy. Extra assistance must be provided at the delivery point to help its safe delivery.
© Jack Sealey Limited
30 & 50TONNE FLOOR TYPE PREMIER AIR/
HYDRAULIC PRESS
MODEL NO:
Wear protective
Wear safety
gloves
footwear
Original Language Version
PPF301S, PPF501S
Wear protective
Warning
clothing
crushing
of hands
PPF301S, PPF501S Issue:2 (3)27/06/22
No reaching
Piston rod
in
should face the
workpiece

Advertisement

loading

Summary of Contents for Sealey PPF301S

  • Page 1 WARNING! DO NOT use brake fluid, or any fluid other than a good quality jack oil, such as SEALEY HYDRAULIC JACK OIL, as ‰...
  • Page 2: Specification

    3. SPECIFICATION Model: ..................PPF301S ............... PPF501S Air Consumption: ................4.5cfm ..............4.5cfm Bench or Floor Mounting: ..............Floor ..............Floor Capacity: ..................30tonne ..............50tonne Gauge Included: ..................Yes ................ Yes Lateral Ram Travel: ................. 200mm ..............280mm Maximum Height - Ram to Table: ............ 875mm ..............860mm Minimum Height - Ram to Table: ............
  • Page 3: Operation

    When the press is not in use, ensure that the ram is retracted fully to help avoid corrosion. 5.3. SADDLE AND PIN OPERATION fig 11A and fig 11B fig.11B fig.11A PPF301S, PPF501S Issue:2 (3)27/06/22 Original Language Version © Jack Sealey Limited...
  • Page 4: Maintenance

    Should you need to replace the oil ensure the piston is fully retracted. An excess of oil will render the press inoperative. Use only appropriate Sealey hydraulic jack oil. DO NOT use brake fluid. Contact your local Sealey stockist for details. Purge the system to remove any air.
  • Page 5: Environment Protection

    Important: No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 24 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk...

This manual is also suitable for: