Download Print this page
Sealey PPF301 Instructions

Sealey PPF301 Instructions

Premier air/hydraulic presses 20 & 30 tonne floor type with sliding ram and foot pedal

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions
and maintained properly, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT
CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL
INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to Instruction
Wear Eye
Manual
Protection
1. SAFETY
 Familiarise yourself with the applications, limitations and hazards of the press.
 Maintain the press in good condition (use an authorised service agent).
 Replace or repair damaged parts. Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
 Keep the press clean for best and safest performance.
 Locate the press in a suitable work area, on a surface that is stable, level, dry, not slippery, and capable of sustaining the load.
 Keep area clean and tidy and free from unrelated materials, and ensure there is adequate lighting.
 WARNING! Always wear approved eye or face protection when operating the press.
 Remove ill fitting clothing. Remove ties, watches, rings and other loose jewellery, and contain long hair.
 Keep hands and body clear of the work table when operating the press.
 Maintain correct balance and footing. DO NOT over reach. Ensure the floor is not slippery and wear non-slip shoes.
 Keep children and unauthorised persons away from the working area.
 DO NOT use the press for a task it is not designed to perform.
 DO NOT adjust or tamper with the safety valve, or make any modifications to the press.
 DO NOT exceed the rated capacity of the press. Avoid applying excessive force, use the pressure gauge to determine the applied load.
 DO NOT allow the workpiece or the arbor plates to fall from the press table
 DO NOT get the press wet or use in damp or wet locations or areas where there is condensation.
 DO NOT operate the press when you are tired or under the influence of alcohol, drugs or intoxicating medication.
 DO NOT climb upon the press.
 DO NOT use if damaged, or if press has been subjected to a shock load.
 DO NOT operate the press if any parts are missing as this may cause failure and/or possible personal injury.
 DO NOT use the press to compress a spring or any other item that could disengage and cause a potential hazard.
 DO NOT stand directly in front of loaded press and never leave loaded press unattended.
 DO NOT allow untrained persons to operate the press.
 DANGER! This model is purpose designed to withstand greater loads than the hydraulic unit can develop. For safety reasons, always
ensure the workpiece and press tools are secured on the table and will not flex or suddenly give way, causing danger to operator or
the workpiece.
 WARNING: DO NOT use brake fluid or any fluid other than a good quality jack oil, such as SEALEY HYDRAULIC JACK OIL,
as this may cause serious damage to the press and will invalidate the warranty.
 When not in use, release pressure from the pump and clean the press. Stand or store the arbors in a safe, childproof location.
2. INTRODUCTION
Professional range of floor and bench mount presses, ranging from 15tonne to 50tonne. Hydraulic elements are mounted in the frame to maximise
workspace and protect components. Floor models incorporate a fast approach feature (foot pedal or handle operated depending on model). Model
No's PPF301 and PPF501 are air/hydraulic and fully operated by foot pedal to keep hands free for fine positioning of the workpiece. Suitable for
workshop use or by the serious motoring enthusiast.
3. SPECIFICATION
Model No: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PPF301 . . . . . . . . . . . . . . . . . . . . . . . PPF501
Bench or Floor Mounting:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Floor . . . . . . . . . . . . . . . . . . . . . . . . . . . Floor
Type:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air/Hydraulic . . . . . . . . . . . . . . . Air/Hydraulic
Capacity:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30tonne . . . . . . . . . . . . . . . . . . . . . . . 50tonne
Ram Stroke: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195mm. . . . . . . . . . . . . . . . . . . . . . . . 195mm
Ram Ø: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60mm. . . . . . . . . . . . . . . . . . . . . . . . . . 60mm
Lateral Ram Travel: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250mm. . . . . . . . . . . . . . . . . . . . . . . . 230mm
Maximum Height - Ram to Table:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 470mm. . . . . . . . . . . . . . . . . . . . . . . . 465mm
Minimum Height - Ram to Table: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85mm. . . . . . . . . . . . . . . . . . . . . . . . . . 80mm
Table Aperture: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165mm. . . . . . . . . . . . . . . . . . . . . . . . 165mm
Working Table Depth: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190mm. . . . . . . . . . . . . . . . . . . . . . . . 190mm
Working Table Width: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 530mm. . . . . . . . . . . . . . . . . . . . . . . . 720mm
Overall Height: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1920mm. . . . . . . . . . . . . . . . . . . . . . 1920mm
Gauge Included: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Yes
Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180kg. . . . . . . . . . . . . . . . . . . . . . . . . . .225kg
© Jack Sealey Limited
INSTRUCTIONS FOR:
PREMIER AIR/HYDRAULIC PRESSES
20 & 30 TONNE FLOOR TYPE WITH SLIDING
RAM AND FOOT PEDAL
PPF301, PPF501
MODEL NO'S
Original Language Version
PPF301, PPF501 Issue:3(I) 21/07/17

Advertisement

loading

Summary of Contents for Sealey PPF301

  • Page 1 Floor models incorporate a fast approach feature (foot pedal or handle operated depending on model). Model No's PPF301 and PPF501 are air/hydraulic and fully operated by foot pedal to keep hands free for fine positioning of the workpiece. Suitable for workshop use or by the serious motoring enthusiast.
  • Page 2 1/2” (fig.10). 4.4.2. An air supply pressure of between 7 and 10bar (100 -145psi) is recommended. fig.10 Original Language Version © Jack Sealey Limited PPF301, PPF501 Issue:3(I) 21/07/17...
  • Page 3 6.2. Should you need to check or replace oil ensure piston is fully retracted. Remove the oil reservoir filler plug (fig.11) and top up using Sealey hydraulic jack oil. DO NOT use brake fluid. Contact your local Sealey dealer for details. After filling purge the system to remove any air.

This manual is also suitable for:

Ppf501