g. X-radiation – TUBE: The primary source of X-
radiation in this receiver is the picture tube. The tube
utilized for the above mentioned function in this
chassis is specially constructed to limit X-radiation
emissions.
For continued X-radiation protection, the replacement
tube must be the same type as the original, Sharp
approved type.
When troubleshooting and making test measure-
ments in a receiver with a problem of excessive high
voltage, avoid being unnecessarily close to the pic-
ture tube and the high voltage component.
Do not operate the chassis longer than is necessary
to locate the cause of excessive voltage.
Shield Plate B (1.6mm)
Detailing X-radiation shield, ( ) plate thickness
)LJ  ,QVWDOODWLRQ RI VKLHOG OHQV VKLHOG FRYHU DQG VKLHOG SODWHV REOLTXH YLHZ 
(Note: This figure is for your reference. The body's
actual shape is different from this one.)
Shield Plate A (1.6mm)
Glass Lens for Shielding
Shield Plate B (1.6mm)
Shield Plate C (1.6mm)
5
Shield Plate B (1.6mm)
61R-WP5H
55R-WP5H