Page 1
• ¼ Turn valves handmade at Nicolazzi Factory • Lead Free Brass Compliant to AZ/NZS 3718 • Suitable even and uneven pressure WM22315 AS/NZS3662 • Handles are interchangeable Canterbury Sink & Tap Co. Max/Min Operating Pressure: 100/500kPa Further information Phone (03) 9761 4603 sales@sinkandtap.com.au...
Page 2
Important Notice Model : Z3314--44 CAREFULLY READ THROUGH THESE INSTRUCTIONS BEFORE INSTALLATION AND USE OF ALL TAP WARE AND WALL VALVES INSTALLATION and WARRANTY INSTRUCTIONS TECHNICAL INFORMATION All flexible hoses are designed and manufactured for use with water in exposed locations only. Do not expose to household cleaners, chlorine, chloride, hydrochloric acid or other corrosive chemicals.
Page 3
Installation Instructions Model : Z3314--44 Preparation Tap body Tap body cut out hole sizes : Maximum 33mm diameter. Under side clearance : Maximum 60mm Tap section Flush out the pipework to remove any foreign matter. Tap section cut out hole sizes : Maximum 33mm diameter. ...
Page 4
Installation Instructions Model : Z3314--44 Thread the bottom brass lock nut 1, followed by the ❶ bottom rubber washer 2, onto the Side body 3, thread section. Repeat for the opposite side. Insert the Side body 3, through the tap hole cut outs in the counter top.
Page 5
Installation Instructions Model : Z3314--44 Thread the bottom brass lock nut 9, followed ❹ by the bottom rubber washer 10, onto the Diverter body 8, thread section. Insert the Diverter body 8, through the tap hole cut out in the counter top. ...
Page 6
Installation Instructions Model : Z3314--44 ❼ Install the water supply hose 19, into tap the body spout 18. - Note: Hand tighten only, DO NOT over tighten- 19! ❽ Install the supplied mounting stud 20, into tap the body spout and verify that they are securely installed.
Page 7
Installation Instructions Model : Z3314--44 Under the sink, stack the supplied half ring ❿ rubber gasket 22, above the half ring mounting plate 23, and feed them onto the stud. Then screw the mounting nut 24, onto the stud. Screw the mounting stud until the half ring rubber gasket mates up with the underside of the sink.
Page 8
Installation Instructions Model : Z3314--44 ⓬ Connect main Hot and Cold water supplies to the Tap side body thread sections, using the correct flexi tail hoses. From the front view, the Cold water supply is connected on the right hand side, with the Hot water supply on the Left hand side ...
Page 9
Installation Instructions Model : Z3314--44 ⓮ Install Hand spay hand set 31, to the curved joint holder 28. Ensure that the Check valve 30, is inserted into the end recess of the hand set. Place the rubber washer 29, between the hand set 31, and the curved joint holder hand firmly screw into place.
Page 10
Installation Instructions Model : Z3314--44 ⓰ Install the tap spout flexi hose 38, to the Diverter output. Place the rubber washer 39, between the female hose thread connecter, and the Diverter output. Before use Turn on the Hot and Cold supplies to the tap. ...
Page 11
Spare Parts list Model : Z3314--44 Further information Phone (03) 9761 4603 sales@sinkandtap.com.au...
Page 12
Spare Parts list Model : Z3314--44 Further information Phone (03) 9761 4603 sales@sinkandtap.com.au...
Page 13
Care and Maintenance Instructions Model : Z3314--44 Removing and replacing a handle MODEL SHOWN :Z3314 ❶ ❷ Loosen and unscrew the retaining flange Once totally loose, simply remove the A, from the tap body. handle from cartridge spline. ...
Page 14
Care and Maintenance Instructions Model : Z3314--44 MAINTENANCE FOR FIVE HOLE/THREE LEVER TAPWARE INSTRUCTIONS FOR REPLACEMENT OF THE HOT OR COLD CARTRIDGE Do not replace the cartridge if there is low flow or no flow. Low flow or no flow is caused by obstruction or kinking of supply hoses.
Page 15
Care and Maintenance Instructions Model : Z3314--44 LOW FLOW OR NO FLOW TROUBLESHOOTING INSTRUCTIONS Current bathroom taps have a max flow rate of 7 Litres per minute from the aerator and the hand spray. If you are experiencing low flow from the spout: Do not change the cartridge •...
Page 16
Care and Maintenance Instructions Model : Z3314--44 Care of external finishes Nicolazzi products are all authentic finishes that have not been coated with any product. After each use, pat the fixture down to remove any excess water. This will prevent any water spotting or mineral build-up. Use only soft liquid soap and water to clean the surface.
Need help?
Do you have a question about the ARENA Z3314-44 and is the answer not in the manual?