Fuses

A number of fuses protect various circuits and
components. All the fuses except F21 are located
on the interface board, which is located inside the
control box. F21 is located in the fuse holder
between the REDB and 2 wires that go from the
battery to the 2 terminal on the interface board.
Refer to the appropriate Microprocessor
Diagnostic Manual for a complete list of the size
and function of the fuses.
Fuse
Size
Function
F2
15A
Power to On/Off Switch
F3
40A
Fuel Sol Pull-In/Starter Circuit
F4
None
No Fuse - All Bosch and Thermo
King Alternators
2A
2A Fuse - All Prestolite Alternators
F5
40A
Preheat Circuit
F6
15A
Damper and High Speed Circuits
F7
2A
8XP Circuit - Controller On
Feedback to HMI
F8
5A
CAN Connector J12
F9
5A
CAN Connector J14
F10
10A
8X Power (Install fuse in upper
position)
F11
10A
Power to Drain Tube Heater Relay
for Remote Evaporator (Not Used)
F12
5A
CAN Connector J13
F13
2A
8FC Circuit (Remote Lights)
F15
P/S
On/Off Relay
F21
60A
Main Fuse (2 Circuit)
F20
2A
Alternator Sense
F22
Not Used
F23
Not Used
F25
7.5A
HPCO/Run Circuit
F4 Remove fuse F4 for Model 30 units with
Australian Bosch or Thermo King Alternators. Install
fuse F4 for Model 50 units with Prestolite Alternator.
F10 When fuse F10 is installed in the upper position
the On/Off keys on the HMI turn the unit on and off.
When fuse F10 is installed in the lower position the
unit will start and run without the HMI control panel.
F15 The device identified as F15 is a poly switch.
These over-current devices reset automatically and
are not replaceable.
Electrical Maintenance
Figure 148: Interface Board
75

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T-1000R Series and is the answer not in the manual?

Questions and answers

Zach Human
January 20, 2025

What is the electric power requirements

1 comments:
Mr. Anderson
February 4, 2025

The electric power requirements for the Thermo King T-1000R Series are:

- Voltage/Phase/Frequency:
- 230/3/50
- 208-230/3/60
- 400/3/50
- 460/3/60

- Horsepower:
- 10.0 HP for 230/3/50 and 400/3/50
- 12.0 HP for 208-230/3/60 and 460/3/60

- Kilowatts:
- 7.5 kW for 230/3/50 and 400/3/50
- 8.9 kW for 208-230/3/60 and 460/3/60

- Full Load Amps:
- 22.5 amps for 230/3/50
- 28.8 amps for 208-230/3/60
- 17.0 amps for 400/3/50
- 14.4 amps for 460/3/60

- Overload Relay Setting:
- 25 amps for 230/3/50
- 32 amps for 208-230/3/60
- 16 amps for 400/3/50 and 460/3/60

- Standby Power Requirements:
- Supply Circuit Breaker:
- 200-230/3/50-60: 50 amps
- 380-460/3/50-60: 20 amps

- Extension Cord Size:
- Up to 50 ft: 10 gauge
- 75 ft: 8 gauge

This answer is automatically generated

Majid ali
February 7, 2025

Electric power not stop.only 5 minat stop and power cut

This manual is also suitable for:

T-600rT-800r

Table of Contents

Save PDF