BIOSTRENGTH LINE ....................11 3.1.1 UNITY MINI ......................11 3.1.2 10” DISPLAY ......................11 CARDIO MACHINES (NOT AVAILABLE FOR BIOCIRCUIT FREE) AND UNITY SELF (NOT NECESSARY FOR BIOCIRCUIT FREE*) ...........12 3.2.1 DISPLAY UNITY ....................12 TECHNICAL INFO AND REQUIREMENTS ............13 TECHNICAL DATA AND POWER REQUIREMENTS ..........13 RECOMMENDATION: RCD SWITCH TYPE F ............15...
Page 4
BIOCIRCUIT - BIOCIRCUIT FREE Pre-Installation Requirements Rev. 6.0 5.4.4 PROXY ........................27 5.4.5 NETWORK BANDWIDTH REQUIREMENTS ............27 SPECIFIC REQUIREMENTS FOR UNITY SELF OF BIOCIRCUIT .......28 ACKNOWLEDGEMENT AND ACCEPTANCE ...........29 LIST OF CHANGES FOR MANUAL VERSION ..........31 REVISION 1.0 ......................31 REVISION 2.0 ......................31 REVISION 3.0 ......................31 REVISION 4.0 ......................31...
Page 5
This document contains proprietary information that is covered by copyright. All rights re- served. No part of this document may be circulated, copied, reproduced or translated into another language without the prior written consent of Technogym. Additional information may be included in the After Sales technical documents, available in the Technogym ServicePortal.
BIOCIRCUIT - BIOCIRCUIT FREE Pre-Installation Requirements Rev. 6.0 GENERAL WARNINGS This manual includes informative notes with specific meanings: Safety signs classified according to the relative seriousness of the potential hazards: DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
(Switch, Router, firewall) and any wireless network are at the expense of the customer. ▪ Technogym warns that the efficiency and correct operation of the equipment and of the my- wellness Cloud services depend on the technical characteristics of the hardware that is in- stalled.
BIOCIRCUIT - BIOCIRCUIT FREE Pre-Installation Requirements Rev. 6.0 DISPLAY 3.1 BIOSTRENGTH LINE 3.1.1 UNITY MINI Equipment of BIOSTRENGTH LINE may be fitted with UNITY MINI Display. Fig. 1 3.1.2 10” DISPLAY Equipment of BIOSTRENGTH LINE may be fitted with 10” Display.
1 per location to let end users manage their prescribed workouts. 3.2.1 DISPLAY UNITY RUN, BIKE, NEW SYNCHRO machines and UNITY SELF are fitted with UNITY Display. Fig. 3 - Run machine Fig. 4 - Unity Self (Not necessary for Biocircuit Free) - 12 - PIR-00063-EN- Uncontrolled copy if printed...
BIOCIRCUIT - BIOCIRCUIT FREE Pre-Installation Requirements Rev. 6.0 TECHNICAL INFO AND REQUIREMENTS 4.1 TECHNICAL DATA AND POWER REQUIREMENTS POWER SUPPLY BIOSTRENGTH LINE Multivoltage: 100÷240Vac, 50/60Hz BIKE ARTIS NEW SYNCHRO ARTIS UNITY SELF RUN ARTIS Europe: 200÷240Vac, 50/60Hz Multivoltage: 100÷240Vac, 50/60Hz Tab.
Page 14
BIOCIRCUIT - BIOCIRCUIT FREE Pre-Installation Requirements Rev. 6.0 USEFUL GUIDELINES FOR CIRCUIT BREAKERS BIOSTRENGTH LINE Power Supply: 110 Vac: RECOMMENDED a 20 Amp Single Pole (except LEG PRESS) AFCI circuit breaker for each 2 equipment of Biostrength Line Power Supply: 220 Vac: RECOMMENDED a C10 circuit breaker for...
There must be a dedicated power supply line for each machine and Unity Self. Connection in series via “Bridge” cable is not certified for BIOCIRCUIT and must not be realised. The wall socket of the Unity Self must provide power of at least 800 watt and be used exclusively for Unity Self.
BIOCIRCUIT - BIOCIRCUIT FREE Pre-Installation Requirements Rev. 6.0 4.4 POSITION OF THE PRODUCT SOCKET The Chest Press, Shoulder Press, Low Row, Vertical traction, Lower Back and Total Abdominal machines have the product socket, positioned on the front side, as shown below.
Page 17
BIOCIRCUIT - BIOCIRCUIT FREE Pre-Installation Requirements Rev. 6.0 Fig. 7 - Leg Press (Left Side) Fig. 8 - Bike PIR-00063-EN- Uncontrolled copy if printed - 17 -...
Technogym doesn’t guarantee the correct functioning of BIOCIRCUIT, if machines of BIOCIRCUIT are connected to a data network both via wireless and via ethernet cable: mixed configuration. Therefore, you must have all BIOCIRCUIT equipment connected to a data network via wireless or via cable.
5.3 ROUTER WITH 4G FAILOVER IN CASE OF UNSTABLE INTERNET CONNECTION Field of Application: Biocircuit. Technogym strongly recommends to use a ROUTER WITH 4G FAILOVER, in case of unstable internet connection. The Modem router Nighthawk 4G LTE has been tested and guarantees the correct functioning of Biocircuit.
REQUIREMENTS 5.4.1 Ethernet cabled network (Recommended) Field of Application: Biocircuit - Biocircuit Free: Unity Self (not necessary for Biocircuit Free), Biostrength Line, Cardio equipment (not available fot Biocircuit Free). Please note that UNITY SELF MUST BE CONNECTED TO A DATA NETWORK, BY ETHERNET CABLE.
Security Protocol: WEP, WPA/WPA2, open (free) network; Please note that the protocol WPA2 Enterprise is not supported. • Technogym requires mandatory to use only one dedicated Professional Access Point for each BIOCIRCUIT, with only one SSID (Service Set Identifier). The SSID must not be hid- den; • DHCP enabled;...
BIOCIRCUIT - BIOCIRCUIT FREE Pre-Installation Requirements Rev. 6.0 5.5 SPECIFIC REQUIREMENTS FOR UNITY SELF OF BIOCIRCUIT As defined above: UNITY SELF MUST BE CONNECTED TO A DATA NETWORK, BY ETHERNET CABLE. Compliant UNITY SELF: starting from UNITY SELF ARTIS 2016 (E0204V15) / UNITY SELF AR- TIS 2017 (E0204V16).
Inserted technical info for the new equipment NEW SYNCHRO that can be inserted in the Biocir- cuit. Detailed the network architecture; Deatiled the network requirements for equipment and Unity Self of Biocircuit. PIR-00063-EN- Uncontrolled copy if printed - 31 -...
Page 32
BIOCIRCUIT - BIOCIRCUIT FREE Pre-Installation Requirements Rev. 6.0 7.5 REVISION 5.0 Extended the scope of the document to BIOCIRCUIT FREE. Inserted the reference to the new display 10”. New paragraph RECOMMENDATION: RCD SWITCH TYPE F. 7.6 REVISION 6.0 Modified § 5.4.2 Wi-Fi Network: the Wi-Fi Auto Channel must be disabled.
Need help?
Do you have a question about the BIOCIRCUIT and is the answer not in the manual?
Questions and answers