Service Modes, Error Codes, and Fault Finding
Table 5-2 Error Code Table GDE
Error
Error Name
A
Vertical Output Failure
B
Horizontal Flyback Failure
C
HOP Initialization Failure
D
DAC Initialization Failure
E
Auto Convergence Failure
F
Set References Failure
G
Sensor Pattern Failure
H
General Initialization Failure
I
HOP IIC Error
J
DAC IIC Error
K
ST2050A IIC Error
L
Main EEPROM IIC Error
M
EEPROM Factory Service 1 Failure This error indicates there was a data integrity failure when accessing the main EEPROM factory/
N
EEPROM Factory Service 2 Failure This error indicates there was a data integrity failure when accessing the main EEPROM factory/
O
EEPROM Factory Service 3 Failure This error indicates there was a data integrity failure when accessing the main EEPROM factory/
P
EEPROM Customer Data 1 Failure This error indicates there was a data integrity failure when accessing the main EEPROM custom-
Q
EEPROM Customer Data 2 Failure This error indicates there was a data integrity failure when accessing the main EEPROM custom-
R
EEPROM Customer Data 3 Failure This error indicates there was a data integrity failure when accessing the main EEPROM custom-
S
EEPROM Factory Service 4 Failure This error indicates there was a data integrity failure when accessing the main EEPROM factory/
T
EEPROM Factory Service 5 Failure This error indicates there was a data integrity failure when accessing the main EEPROM factory/
U
EEPROM Factory Service 6 Failure This error indicates there was a data integrity failure when accessing the main EEPROM factory/
V
EEPROM Customer Data 4 Failure This error indicates there was a data integrity failure when accessing the main EEPROM custom-
W
EEPROM Customer Data 5 Failure This error indicates there was a data integrity failure when accessing the main EEPROM custom-
X
EEPROM Customer Data 6 Failure This error indicates there was a data integrity failure when accessing the main EEPROM custom-
Y
EEPROM Scratch Pad Failure
Description
This error indicates the Vertical Deflection pulse received at pin 9 on the TDA933x is not correct.
This can be caused by a failure in the HOP board or the Scan Board.
This error indicates the Horizontal Flyback pulse received at pin 13 on the TDA933x is not correct.
This can be caused by a failure in the HOP board or the Scan Board.
This error indicates the TDA933x was not initialized correctly during ACS board power up.
This can be caused by an error on the ACS board, the HOP board or the Small Signal Carrier
board.
This error indicates the TDA8444 was not initialized correctly during ACS board power up.
This can be caused by an error on the ACS board, the HOP board or the Small Signal Carrier
board.
This error indicates an error during the Auto Convergence process.
This error indicates there was an error while setting the reference values.
This error indicates there is an error in a sensor or an error occurred while walking a pattern
across a sensor.
This error indicates a general initialization software failure. This error is caused by the ACS board.
This error indicates there was an IIC error while accessing the HOP.
This can be caused by an error on the ACS board, the HOP board or the Small Signal Carrier.
This error indicates there was an IIC error while accessing the DAC.
This can be caused by an error on the ACS board, the HOP board or the Small Signal Carrier.
This error indicates there was an IIC error while accessing the ST2050A.
This can be caused by an error on the ACS board.
This error indicates there was an IIC error while accessing the main EEPROM on the ACS board.
This can be caused by an error on the ACS board.
service area 1.
This error is caused by corrupted EEPROM data that does not match the data integrity CRC.
service area 2.
This error is caused by corrupted EEPROM data that does not match the data integrity CRC.
service area 3.
This error is caused by corrupted EEPROM data that does not match the data integrity CRC.
er data area 1.
This error is caused by corrupted EEPROM data that does not match the data integrity CRC.
er data area 2.
This error is caused by corrupted EEPROM data that does not match the data integrity CRC.
er data area 3.
This error is caused by corrupted EEPROM data that does not match the data integrity CRC.
service area 4.
This error is caused by corrupted EEPROM data that does not match the data integrity CRC.
service area 5.
This error is caused by corrupted EEPROM data that does not match the data integrity CRC.
service area 6.
This error is caused by corrupted EEPROM data that does not match the data integrity CRC.
er data area 4.
This error is caused by corrupted EEPROM data that does not match the data integrity CRC.
er data area 5.
This error is caused by corrupted EEPROM data that does not match the data integrity CRC.
er data area 6.
This error is caused by corrupted EEPROM data that does not match the data integrity CRC.
This error indicates there was a data integrity failure when accessing the main EEPROM scratch
pad area.
This error is caused by corrupted EEPROM data that does not match the data integrity CRC.