Filter Panes - KBL 5600 Operating And Maintenance

Hide thumbs Also See for 5600:
Table of Contents

Advertisement

5.3

Filter panes

The facial tanners are equipped with an additional safety
Safety function
function. Behind each of the filter panes there is a safety switch
that switches off the burner in the case of a missing or broken
pane.
Do not operate the tanning system with a defective "lter pane.
Carry out regular visual inspections!
Filter panes have to be replaced only by those of the same type!
The "lter panes may be dismantled and replaced by trained
expert staff only.
After dismantling the filter panes (see below), clean them with a
Filter panes in the
standard cleaning agent for glass and a soft cloth or chamois.
canopy or lateral
part
Step
1
Dismantle the acrylic pane of the canopy or of the lateral
part.
2
Undo the screws of the filter pane cover (1), swing it out (2)
and pull it out (3).
3
Carefully and with both hands, press the filter pane down (4)
until the upper springs release the pane (5). Take the pane
out from above (6).
4
After cleaning the pane, mount it again in reverse order.
1
3
1
3
Illustr. 5-7 Remove filter pane cover
The filters are marked with
Mark
„KBL 3020 0191"
Procedure
2
5
2
Illustr. 5-8 Remove pane from the
clamping springs
Reference
see 5.2
Illustr. 5-7
Illustr. 5-8
6
Operation and Service KBL 5600