    Data which all apparatuses have in common ..............33 Views ...........................34 megaSun 5600 Super / Super CPI ..................34 megaSun 5600 Super Power / Super Power CPI...............35 megaSun 5600 Ultra Power / Ultra Power CPI..............35 Wiring diagram ....................36 Mains voltage .
  • Page 3: General Safety Instructions

    See Section 9.1 Timer The apparatuses may only be operated with safety timers which comply with the corresponding standards. KBL-Solarien AG recommends the following timer: megaTimer KBL-Article No. 9100025000. Disconnecting Before opening the apparatus, switch off the fuses to disconnect the system from the voltage supply! Do not operate the sunbed if a filter pane is defective.
  • Page 4: Service Plan

    Reset counter of service hours 5.15 Replace aquaCool nozzles. 1200 For CPI-apparatuses with megaSun CPI-tubes in Eco-mode • Change tubes • Reset counters (8.2.2) • Reset counter of working hours 3000 Replace all the ropes Operation and Service megaSun 5600...
  • Page 5: Optional Equipment

    Channel select next track of the external music source Waste air tube Ø 300 mm, 3 m Central exhaust air element Warm air recirculation legTanner x-traTan Shoulder tanner * the music system should be present Operation and Service megaSun 5600...
  • Page 6: Operation During The Tanning Session

    The running text is displayed as long as the sunbed is in the Main display „waiting position“. When the coin-controlled signal appears, the functions are displayed and the sunbed can be operated by touching the corresponding keys. Any input will be confirmed by a beep tone. Operation and Service megaSun 5600...
  • Page 7: Functions

    When adjusting the volume, the value set between 0 ... 99 % will be displayed in this field for a short time. When adjusting the fan speed, the value set between 20 ... 99 % will be displayed in this field for a short time. Operation and Service megaSun 5600...
  • Page 8 „-„ keys. The volume will be displayed in the numerical field as a value between 0 – 99 %. Press the corresponding sensor key again and again until you have reached the desired volume. * this is only preset if the feature is ordered Operation and Service megaSun 5600...
  • Page 9 Level I To reduce the output to level I, use the field “–”. This step is not available with megaSun 5600 Super, Super Power and Ultra Power UV type 3. Level 0 To switch off the facial tanners completely, touch the “–”...
  • Page 10 The MP3-player is designed in such a way that you only have to change the chip for the mu- sic. KBL delivers all the apparatuses with MP3-players with the music of the CD „megaSun & friends“.
  • Page 11 You can only switch on one colour, but you can switch them all off (see Service level). 48 high-performance diodes for each colour (Red - Green - Blue) produce the mood desired: relaxing blue, stimulating blue and calming green. Operation and Service megaSun 5600...
  • Page 12 “1” and switched off by the „ - “ key below „0“. The display flashes a signal when the function is not activated. KBL can offer 2 aroma fragrances: „Sunrise“ and „Daydream“. The apparatus only has one fragrance which can changed very easily, however.
  • Page 13: Tips For The Studio Operator

    But before doing so, service people should repair the defect. air) Possible reasons of this message can be: • the temperature in the apparatus is too high or • the exhaust vent system is defective For more information see 8.6 Operation and Service megaSun 5600...
  • Page 14: Maintenance Of The Sun Bed

    For a harmless cleaning of the acrylic panes use the special Acrylic panes cleaning and disinfectant fluid „megaClean “ (to be obtained from KBL) which has to be diluted in water at a ratio of 1:13. The canopy can be fixed in the upper position, to perform Fixing the canopy service and maintenance works.
  • Page 15: Dismantling The Acrylic Panes

    Therefore, in order to clean the underside of the base pane and the inner base section, use a slightly damp micro fibre cloth only. You can also use it to clean the shoulder tanner. You can use megaClean as a detergent (spray the cloth with it). Operation and Service megaSun 5600...
  • Page 16 Proceed in the same way with the shoulder tanner. Clean the upper surface of the base pane and fasten it with the two screws. Illustr. 5-4 Pan-head screw Illustr. 5-5 Suspension of the base pane Illustr. 5-6 Duct pane Operation and Service megaSun 5600...
  • Page 17: Filter Panes

    (6). After cleaning the pane, mount it again in reverse order. Illustr. 5-7 Remove filter pane cover Illustr. 5-8 Remove pane from the clamping springs The filters are marked with Mark „KBL 3020 0191“ Operation and Service megaSun 5600...
  • Page 18: Tubes, Facial And Shoulder Tanners

    Tubes with facial without facial Shoulder Burner tanner mode tanner mode tanner Starters Power Power 500 hrs. 500-600 hrs. 500-600 hrs. 800 hrs. 500 hrs. 1000 hrs. 800 hrs. Carry out a reset! Operation and Service megaSun 5600...
  • Page 19: Replacing The Burner Of The Shoulder Tanner

    fit and screw it on. Position the reflector correctly under the Illustr. 5-5-8 chrome covering. To do so, press the reflector slightly to align it. Attach the outer covering vertically and tighten the screw. Operation and Service megaSun 5600...
  • Page 20 Illustr. 5-5-6: Insert the new burner take off the burner including socket and ensure a snug fi t Flat projection Illustr. 5-5-7: Insert the reflector Illustr. 5-5-8: Reflector correctly posi- tioned under the chrome cover Operation and Service megaSun 5600...
  • Page 21: Replacing The Burners Of The Facial Tanner

    Insert the burners in a straight position into their sockets. After being inserted into the socket, the little metal shackle in the centre of the reflector should face the reflector. Operation and Service megaSun 5600...
  • Page 22: Unit Lighting

    (or to the left). Now you can replace the tube. Close the base pane. Illustr. 5-14 Unit lighting in the lower front section and the starter for this tube on the left side. Operation and Service megaSun 5600...
  • Page 23 5600: Below the canopy casing you will find two Canopy lighting energy saving lamps and a dual ballast. To replace the lamps touch it at the lamp socket. Step Procedure Reference Remove the chromium-plated front cover. Unscrew the next cover...
  • Page 24: Filter Mats

    The filter mat is located behind the decorative lighting in the Filter mat in the base section. Open the bed pane and remove the fluorescent base section tube. Now you have free access to the filter mat. Illustr. 5-17 Filter mat in the base section Operation and Service megaSun 5600...
  • Page 25: Canopy Drive

    XXL-unit remove the cover plates. Tighten both springs in a balanced way. Check the canopy drive: the canopy remains firm in any position. Close the lateral pane. Illustr. 5-18 Left tension screw Illustr. 5-19 Right tension screw Operation and Service megaSun 5600...
  • Page 26: Cooling System And Exhaust Air

    (tubes). The exhaust air is then blown off through the exhaust flue (green). Illustr. 5-20 Body cooling (blue) and unit Illustr. 5-21 Exhaust fan (mounting cooling (green), filter mats (orange) and picture) exhaust air (red) Operation and Service megaSun 5600...
  • Page 27 (three nozzles). Air nozzles Filter Air condi- tioner, blower and air tube Illustr. 5-24 Cooling principle of base section Operation and Service megaSun 5600...
  • Page 28: Air-Conditioning Unit

    Dirty heat exchangers reduce the performance of the air-conditioning unit. Open the front cover and vacuum-clean the heat exchangers, if necessary. Check the connection hose each time the tubes are replaced. Defective hoses must be replaced. Operation and Service megaSun 5600...
  • Page 29: Condensate Pump

    More about replacement see Section 8.4 . About replacement see Section 8.4 . aroma * this is only preset if the feature is ordered Operation and Service megaSun 5600...
  • Page 30: Music System With Mp3-Player

    (see illustration on the following page). Illustr. 5-26 Installation below the base Illustr. 5-27 MP3 player with music card pane Illustr. 5-28 Construction elements Illustr. 5-29 MP3 for megaVoice * this is only preset if the feature is ordered Operation and Service megaSun 5600...
  • Page 31: Replacing The Aquacool Nozzles

    5.15 Replacing the aquaCool nozzles After 1000 hours of operation, the aquaCool nozzles have to be replaced in order to ensure that aquaCool stays fully operative and efficient. The installation instructions will be enclosed in your spare parts consignment. Operation and Service megaSun 5600...
  • Page 32: Technical Data

    ≥ (140mm x 120 mm x 70mm) with PG 21 Power supply 400 V/3N /50Hz Fuses Circuit breaker 3 pins, 3 x 20 A (RCD) for megaSun 5600 Super Circuit breaker 3-polig, 3 x 25 A (RCD) for megaSun 5600 Super Power und megaSun 5600 Ultra...
  • Page 33: Views

    Views Ø300 1260 Illustr. 6-1 Front view Illustr. 6-2 Lateral view megaSun 5600 Super / Super CPI Super Super CPI Exhaust air appr. 2250m³/h (free blow) appr. 10 m/sec Air velocity Lamps 4x 400 W / megaSun 600 Filter panes...
  • Page 34: Megasun 5600 Super Power / Super Power Cpi

    5600 Super Power / Super Power CPI Super Power Super Power CPI Exhaust air appr. 2250m³/h (free blow) Air velocity appr. 10 m/sec UV3: 4x 400 W / megaSun 600 Lamps UV4: 4x 500 W / megaSun 600 Filter panes...
  • Page 35: Wiring Diagram

    „Technical data“. An FI protective circuit breaker (FI) switch is required in any case. KBL Solarien AG recommend the following type: KBL 3200 0770 00. Should any interference occur due to the operation of your tan- ning unit with the mains, e.g.
  • Page 36: Megavoice Without Music Option

    (connected in parallel, equal-phased). Musikverstärker C Audio- switch megaVoice 3220 2885 00 3220 3230 20 3220 3222 95 E8: 6 5 ... 2 1 MP3 Musik 3220 3222 90 Audio switch MP3 Music MP3 megaVoice Operation and Service megaSun 5600...
  • Page 37: External Music Signal Without Channel Selection

    9100017000, and the music signal is connected to the clamps “IN”. Transformer 9100 0170 00 Music amplifier C Audio- switch megaVoice 3220 2885 00 3220 3230 20 3220 3222 95 E8: 6 5 ... 2 1 Transformer Music signal Operation and Service megaSun 5600...
  • Page 38: External Music Signal With Channel Selection

    3220 3110 00 shielded cablel Masse Music signal Audio switch If the external music signal is a 100V-signal, the transmitter is 100V-Signal introduced into the signal path in front of the Audio switch. (see 7.4) Operation and Service megaSun 5600...
  • Page 39: External Channel Selection

    The following diagram shows the wiring of the channel selection on the audio equipment’s side. Wiring on the audio system of the studio Puls Coding Wiring on the audio system of the studio BCD Coding Operation and Service megaSun 5600...
  • Page 40: External Timer

    A door contact is necessary for the option “cabin fragrance”. Release signal Door contoct Timer Wire No. gnge Cable Ölflex 7 x 1 mm gnge Wire No. Control megaSunm 5600 Start (5V/10mA ... 230V/2A) Operation and Service megaSun 5600...
  • Page 41: Service

    Key 5 to move forward in the menu Key 0 to move backwards in the menu Stop key to leave service level or menu Start key to select a menu item or to save the value displayed Operation and Service megaSun 5600...
  • Page 42: Service Level I

    Date Enter the Service level II PIN II correct PIN Aroma Solar. ON/OFF Booth ON/ OFF B. Inter 00/h Gate ON/OFF B.Timer AR. Cont 99% Aqua ON /OFF AQ. Time Cycle Color R G B Operation and Service megaSun 5600...
  • Page 43 (TUBE) are displayed. Display Selection With the START key you open the sub menus. With the STOP key you go back one level higher. If you have changed a value and you will safe it press START. Operation and Service megaSun 5600...
  • Page 44 3 – 8 Weekday: Monday to Sunday Selection Confirm..Time A/BON and A/BOF Hours / Min Safe * this is only preset if the feature is ordered Operation and Service megaSun 5600...
  • Page 45 GATE ON / OFF: A fragrance is sprayed off in the booth when the door is opened or closed. • B: TIMER: A fragrance can be sprayed off at particular times on the days of the week. There is one interval Operation and Service megaSun 5600...
  • Page 46 AQ.TIME: The spraying cycle is set in the menu CYCLE and the spraying duration in this menu AQ.TIME between 2 ... 6 seconds. The details are set by pressing the „+“ and „-“ keys above or under the time display. Operation and Service megaSun 5600...
  • Page 47 The duration of the breaks of aroma and aqua can be set between 1... 5 minutes. The details are set by pressing the „+“- and „-“ keys above or below the time. Adjust Confirm. + / - Operation and Service megaSun 5600...
  • Page 48 Conrm. + / - Adjust in 2-%- + / - Steps Adjust in 2-%- + / - Steps on / off+ / - Select Conrm. * this is only preset if the feature is ordered Operation and Service megaSun 5600...
  • Page 49: Service Level Ii

    OFFSET A.Start Adjust of the Zero or tube hours start-value Time stamp Display 1st download Time Time stamp Display last download Date Conguration Aroma / Aqua Test Aroma aquaCool aquaExtra Release Software release UV-type, device Operation and Service megaSun 5600...
  • Page 50 OFFSET: Only applicable for tanning units equipped with • ACS. NOTE: Contact your KBL Technical Service before making any changes within this menu item. Increasing the offset value results in the fan starting at a higher speed. The offset value may have to be adjusted, e.g.
  • Page 51 Here you can store the time stamps of the rst and last download Time stamps of the software. Selection First Download Last Download * this is only preset if the feature is ordered Operation and Service megaSun 5600...
  • Page 52 Version This is analogue to the display after the rst start. The version depends on the sunbed: without easyCare (here 5.3) or with easycare (here 1.8). Selection Sub-type of the sun bed UV-type Sun bed Operation and Service megaSun 5600...
  • Page 53: Refilling / Changing Aroma And Aquacool

    Screw the lid on again. Keep clean the end of the tubes when changing the tank (use a plastic bag). Only use the specic water by KBL „aquacool“. Otherwise the nozzles may clog up which might produce infections. Put the constructional elements back into their original place in the sunbed.
  • Page 54: Colour Codes For The Pipes

    flow pipe aquaCool Yellow aroma Abb. 8-2 Compressor Abb. 8-3 aquaCool Abb. 8-4 aroma Abb. 8-5 Canopy underside Abb. 8-6 Canopy upper side Abb. 8-7 Ionizor and aroma pipes Abb. 8-8 Pipes at the nozzles Operation and Service megaSun 5600...
  • Page 55: Error Message

    — SD card not readable — formating or wrong inserted, — Plug at MP3 iInterface or at I²C Audio switch is inserted uncorrect. Conguration error: I²C-Relay board (8) an I²C Relais board (2) at E05BUS:REL the same time connected. Operation and Service megaSun 5600...
  • Page 56: Tanning Instructions

    • Follow the recommendations concerning tanning times and tanning intervals (see 56 ff). • See a doctor when your skin produces persistent swellings or sore points, or when pigmented moles change their appearance. Operation and Service megaSun 5600...
  • Page 57: Super, Uv-Type 3, Inductive

    Skin type II Skin type III Skin type IV Time in min The interval between two tanning sessions has to be at least 48 hours. Max. number of tanning sessions per year @ 15 kJ/m² Operation and Service megaSun 5600...
  • Page 58: Super, Uv-Type 3, Cpi

    Skin type II Skin type III Skin type IV Time in min The interval between two tanning sessions has to be at least 48 hours. Max. number of tanning sessions per year @ 15 kJ/m² Operation and Service megaSun 5600...
  • Page 59: Super, Uv-Type 4, Cpi

    Skin type II Skin type III Skin type IV Time in min The interval between two tanning sessions has to be at least 48 hours. Max. number of tanning sessions per year @ 15 kJ/m² Operation and Service megaSun 5600...
  • Page 60: Super Power, Uv-Type 3, Cpi

    Skin type II Skin type III Skin type IV Time in min The interval between two tanning sessions has to be at least 48 hours. Max. number of tanning sessions per year @ 15 kJ/m² Operation and Service megaSun 5600...
  • Page 61: Super Power, Uv-Type 4, Cpi

    Skin type II Skin type III Skin type IV Time in min The interval between two tanning sessions has to be at least 48 hours. Max. number of tanning sessions per year @ 15 kJ/m² Operation and Service megaSun 5600...
  • Page 62: Ultra Power, Uv-Type 3, Cpi

    Skin type II Skin type III Skin type IV Time in min The interval between two tanning sessions has to be at least 48 hours. Max. number of tanning sessions per year @ 15 kJ/m² Operation and Service megaSun 5600...
  • Page 63: Ultra Power, Uv-Type 4, Cpi

    13 (12)* 17 (15)* 10 (9)* 14 (13)* 18 (16)* The interval between two tanning sessions has to be at least 48 hours. Max. number of tanning sessions per year @ 15 kJ/m² *with legTanner Operation and Service megaSun 5600...