Haier J Series Service Manual page 47

Table of Contents

Advertisement

10.4.10 The communication fault between indoor and outdoor
Indoor display
E7
outdoor display
LED1 flash 15 times
Method of
Communication is detected by checking the indoor PCB and the outdoor PCB.
Malfunction
Detection
Malfunction
Decision
The indoor PCB broken leads to communication fault.
Conditions
Supposed
Causes
Troubleshooting
* Caution Be sure to turn off power switch before connect or disconnect connector, or else
The outdoor PCB broken leads to communication fault.
Communication wiring disconnected.
The indoor PCB is broken.
The outdoor PCB is broken.
The Module PCB is broken.
parts damage may be occurred.
45
Service diagnosis
Domestic air conditioner

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

N series2u50s2sm1fa-3

Table of Contents