Cooling Fan Run-On - Miele H350 Technical Information

Table of Contents

Advertisement

Technical Information
Cooling Air Intake Path
1. Refer to Figure 4-1
2. Via the deflector strips (3)
3. Via the air intake under the door (4)
4. Via the air openings at the rear of the unit (5)
5. Function: To cool the appliance and it's electrical components
Cooling Air Path
1. Refer to Figure 4-1
2. Via the cooling fan (8)
3. Via the air duct (9)
4. Function: Cool air is mixed across the cooling duct with vapors
removed from the oven via the vapor outlet connection
Cooling Air Discharge
1. Refer to Figure 4-1
2.
The cool air and vapor mixture is discharged at the air outlet between
the door handle and fascia panel
4.0.1

Cooling Fan Run-On

The cooling will run during the cooling down cycle until a temperature of
approximately 160 ° F is reached. This will prevent damage caused by
condensation collecting in the appliance. During this cycle the cooling fan
operates at the lowest speed. The length of the run on time is determined
by the temperature inside the oven cavity and may be more then one
hour. Opening the door can terminate the run-on.