Pioneer PDP-503CMX Service Manual page 119

Hide thumbs Also See for PDP-503CMX:
Table of Contents

Advertisement

GS1:
Output data such as version information, hour meter and pulse meter
• Output it according to transmission order and size of the table below.
• Command is invalid except RS-232C factory adjustment mode.
Order
Data Contents
1
Display information
2
Module microcomputer model number
3
Module microcomputer version
4
Panel microcomputer version
5
Panel /FLASH ROM version
6
Hour meter (hour)
7
Pulse meter
8
Main microcomputer model number
9
Main microcomputer version
10
Wide microcomputer version
11
Wide /FLASH ROM version
Display Information
Data
MX5
PDP-503MX (initial value)
MX4
PDP-433MX
MD5
Module 50 inches
MD4
Module 43 inches
HD5
PDP-503HD
HD4
PDP-433HD
GS2:
Output data of power down, temperature and dew drop information
• Output it according to transmission order and size of the table below.
• In the PD (Power Down) of RS-232C factory adjustment mode, NG except dew drop and AUDIO occurs and a command that except for 30
seconds to SD (shut down) is invalid.
Note: When NG occurred in the PD state, do not perform the "FAY" for 30 seconds to SD (Shut Down), and information acquisition is
possible by perform the "GS2" directly.However it is necessary to set ID beforehand.
Order
Data Contents
1
AC information
2
Service parts distinction
3
Hour meter (hour, minute)
4
Power down information
5
Temperature information
6
Dew drop information
7
Panel microcomputer communication
8
DIGITAL EEPROM communication
9
DIGITAL EXPANDER communication
10
Temperature information (TEMP2)
11
Temperature information (TEMP3)
12
Module microcomputer communication
13
Wide microcomputer communication
14
MAIN IIC
15
MAIN EEPROM IIC
16
AUDIO NG
17
FAN NG
Size
3 byte
4 byte
3 byte
3 byte
3 byte
5 byte
7 byte
4 byte
3 byte
3 byte
3 byte
Model
Size
1 byte
1 byte
7 byte
2 byte
3 byte
1 byte
1 byte
1 byte
1 byte
3 byte
3 byte
1 byte
1 byte
1 byte
1 byte
1 byte
1 byte
PDP-503CMX, PDP-503MXE, PDA-5002
Remarks
See below
5691 or F691
Unit: H (time)
Unit: 0.01G (10,000,000)
5692 or F692
Remarks
Always 0 (not used)
0: DIGITAL ASSY adjustment completion
1: DIGITAL ASSY does not adjust (Service Assy)
*****H**M
1st/2nd (Note)
8 bit
1: Dew drop NG
1: Communication NG
1: Communication NG
1: Communication NG
8 bit
8 bit
1: Communication NG
1: Communication NG
1: Communication NG
1: Communication NG
1: AUDIO NG
1: FAN NG
119