Siemens SIMATIC RF610T ATEX System Manual page 468

Hide thumbs Also See for SIMATIC RF610T ATEX:
Table of Contents

Advertisement

System diagnostics
9.1 Diagnostics via the LED displays of the reader
Figure 9-1
468
LED status display (ST1 - ST9) - RF680R/RF685R only
LED operating display
RUN/STOP (R/S)
ERROR (ER)
MAINTENANCE (MAINT)
- only with
RF610R/RF615R/RF680R/
RF685R
POWER (PWR)
PRESENCE (PRE)
- only with
RF610R/RF615R/RF650R
LINK 1 (LK1)
RECEIVE/TRANSMIT 1
(R/T1)
LINK 2 (LK2)
- only with
RF680R/RF685R
RECEIVE/TRANSMIT 2
(R/T2)
- only with
RF680R/RF685R
LED displays of the RF61xR, RF650R and RF68xR reader
Shows whether the reader is ready for operation.
Indicates whether an error has occurred.
Shows whether the reader needs maintenance.
Shows whether the reader is supplied with power.
Among other things, indicates whether or not there are multi-
ple transponders in the antenna field. With the
RF680R/RF685R readers, this is indicated by the status
display.
Indicates that there is a connection via Ethernet interface "1".
Indicates that data is being sent and/or received via Ethernet
interface "1".
Indicates that there is a connection via Ethernet interface "2".
Indicates that data is being sent and/or received via Ethernet
interface "2".
System Manual, 06/2019, J31069-D0171-U001-A22-7618
SIMATIC RF600

Advertisement

Table of Contents
loading

This manual is also suitable for:

6gt2810-2bb80-0ax1

Table of Contents