enware DET5072A-CNBSN Installation And Maintenance Instructions Manual

Wall mounted sensor tap hands-free on/off demand sensor with custodian basin spout

Advertisement

Quick Links

Wall Mounted Sensor Tap Hands-Free
On/Off Demand Sensor with
Custodian
Installation and Maintenance Instructions
DET5072A-CNBSN
I00408_Feb22
Call 1300 369 273
www.enware.com.au
Enware Australia Pty Limited
9 Endeavour Rd Caringbah NSW 2229 Australia
Ph: 02 8536 4000 info
enware.com.au
@
Basin Spout
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DET5072A-CNBSN and is the answer not in the manual?

Questions and answers

Summary of Contents for enware DET5072A-CNBSN

  • Page 1 Wall Mounted Sensor Tap Hands-Free On/Off Demand Sensor with Custodian Basin Spout ® Installation and Maintenance Instructions DET5072A-CNBSN I00408_Feb22 Call 1300 369 273 www.enware.com.au Enware Australia Pty Limited 9 Endeavour Rd Caringbah NSW 2229 Australia Ph: 02 8536 4000 info enware.com.au...
  • Page 2: Product Description

    Enware Touch-Free Wall Sensor Tap is a sensor operated, hands-free tap that is installed onto walls above sinks, basins or wash troughs. It operates by sensing a hand in front of the sensor unit. Once the sensor is activated, the valve will remain open and water will flow until the hand is again placed in front of the sensor, closing the solenoid valve.
  • Page 3: Technical Data

    The optional settings are available at the time of ordering. Contact Enware for more details. installation compliance *Enware products are to be installed in accordance with the Plumbing Code of Australia (PCA) and AS/NZS3500. Installations not complying with PCA and AS/NZS 3500 may void the product and performance warranty provisions.
  • Page 4: Location Of Sensor

    Do not install sensor directly in front of a mirror. SET-OUT HEIGHT Suggested heights from finished floor: Spout 1050mm outlet 1120mm to point of water discharge (Australasian Health Facility Guidelines) Top of 850mm basin 865mm (Australasian Health Facility Guide- lines) Call 1300 369 273 www.enware.com.au...
  • Page 5 WARNING: Do not cut the wires or extend Thermostatic Mixing Valve be used to the existing cables without using the provide pre-mixed water to the valve. correct lead extension from Enware, as this will void warranty. www.enware.com.au Call 1300 369 273...
  • Page 6: Installation In-Wall

    SEE IMAGE 01 Call 1300 369 273 www.enware.com.au...
  • Page 7 120mm high rectangular hole, and at least 65mm deep to allow for installation of bracket. Sensor Wall Cut Out for Sensor Bracket cable to come through the top, bottom, or back of sensor inside wall. SEE IMAGE 05 IMAGE 05 www.enware.com.au Call 1300 369 273...
  • Page 8 3 metre lead from the sensor to the solenoid. Additional lead lengths up to 15 metres 4.5m can be accommodated with extension cables (available separately from Enware). SEE IMAGE 06 TRANSFORMER CABLE WARNING: Do not cut the electrical cable of IMAGE 06 the sensor tap, or alter the product in any way to suit installation.
  • Page 9 Sensor components are fragile and sensitive. See Operating Instructions overpage. Do not force the sensor plate to fit onto wall, or attempt to disassemble sensor components, as this could result in damage to sensor and would void warranty. www.enware.com.au Call 1300 369 273...
  • Page 10: To Turn Off

    When hand is within sensor range, sensor responds with a Red LED light in the sensor lens. *Longer flow time settings are available at the time of ordering – contact Enware for more information. Hand too close to sensor Wave quickly in front of sensor...
  • Page 11: Troubleshooting

    Replace solenoid valve Tap/ water turns off slowly Debris in solenoid valve Take solenoid apart and clean diaphragm. Refer to Solenoid Maintenance section. Solenoid diaphragm is Replace solenoid diaphragm damaged or solenoid. Refer to Solenoid Maintenance section. www.enware.com.au Call 1300 369 273...
  • Page 12: Spare Parts

    PART ENWARE PRODUCT CODE Sensor – On / Off Demand ENMS133A (Stainless steel plate, sensor connector cable) Solenoid 1/2” – DC 24v WMS8200 (includes DC solenoid 1/2”, 2x 1/2” nipples) Solenoid Service Kit - DC WMS8302 (includes diaphragm, piston and spring to suit DC solenoid 1/2”) Transformer –...
  • Page 13: Service And Maintenance

    Take note of the order of parts assembled. SEE IMAGES 10, 11 4. Check seat and diaphragm for debris or any damage. SEE IMAGE 12 IMAGE 12 www.enware.com.au Call 1300 369 273...
  • Page 14 DIRECTION OF FLOW 11. Finally place the black coil body back over the core tube, and tighten the hex nut back up. IMAGE 15 DIRECTION OF FLOW IMAGE 16 DIRECTION OF FLOW IMAGE 17 Call 1300 369 273 www.enware.com.au...
  • Page 15: Replacing The Sensor

    REPLACING THE SENSOR CLEANING The Sensor is a non serviceable product. If damaged Enware Product should be cleaned with a soft damp the sensor must be replaced. cloth using only mild liquid detergent or soap and water. Do not use cleaning agents containing a 1.
  • Page 16: Making A Claim

    All notifications and accompanying forms must be sent to us marked for the attention of the Enware Australia Pty Except as provided or referred to in this document, we Limited, 9 Endeavour Road, Caringbah NSW 2229. We...