Wall mounted single inlet FS021 FS020 Wall mounted recessed FS023 (concealed in wall) Installing the riser, pot filler & spray arm WATER CONNECTIONS OPERATING INSTRUCTIONS CLEANING SERVICE AND MAINTENANCE SPARE PARTS TROUBLESHOOTING PRODUCT WARRANTY FOR AUSTRALIA Call 1300 369 273 www.enware.com.au...
Page 3
TROUBLESHOOTING food service pre-rinse assemblies Thank you for choosing Enware’s Food Service Tapware . Designed and manufactured in Australia, the Food Service Range is built using premium quality hose, brass and stainless steel to provide maximum strength and durability. It can quickly and efficiently remove waste material from plates, pans and utensils prior to them being washed.
Page 5
For use with potable water only. installation compliance *Enware products are to be installed in accordance with the Plumbing Code of Australia (PCA), AS/NZS3500 and the manufacturer’s instructions. Installations not complying with PCA, AS/NZS 3500 or the manufacturer’s instructions may void the product and performance warranty provisions.
Page 6
• Ensure water pressures for hot and cold supplies Shorter riser, hose & spring guard options are are relatively balanced. If not, one side may available from Enware override the other. A pressure reduction valve • Check that wall bracket can be installed on a stable may be required to address any imbalance in wall surface.
Do not over-tighten. (Using excessive force may result in damage to the black plastic spacer.) SEE IMAGE 5. IMAGE 5 5. Proceed to installation of riser, pot filler & spray arm – page 15 www.enware.com.au Call 1300 369 273...
IMAGE 8 IMAGE 9 4. Fit the other flexible inlet hose onto body. 5. Proceed to installation of riser, pot filler & IMAGE 10 spray arm – page 15 Call 1300 369 273 www.enware.com.au...
From underneath the bench, fit lock nuts onto the tails and tighten firmly using a spanner. IMAGE 12 4. Proceed to installation of riser, pot filler & spray arm – page 15 www.enware.com.au Call 1300 369 273...
1/2” brass nut on. Note the orientation of the grub screw on the base, then tighten the brass nut firmly using a spanner. SEE IMAGE 17 Call 1300 369 273 www.enware.com.au...
Page 11
Tighten using the 3mm Allen key provided, then fit indicator button holder into the lever handle top by pushing it 13. Proceed to installation of riser, pot filler & spray arm – page 15 IMAGE 25 www.enware.com.au Call 1300 369 273...
7. Once the tap frame has fully engaged, screw each nut onto wall base and tighten with a spanner. 8. Proceed to installation of riser, pot filler & spray arm – page 15 IMAGE 29 Call 1300 369 273 www.enware.com.au...
Screw wall base onto the 1/2” thread, and tighten firmly. Make sure the wall base is fitted plumb (facing straight up). 5. Proceed to installation of riser, pot filler & spray arm – page 15 www.enware.com.au Call 1300 369 273...
Page 14
IMAGE 30 jumper valve). Installations outside of this range may require extended SBA’s (spindles) or trouble domes (available from Enware). SEE IMAGE 30 3. Flush the line thoroughly before connecting tap fittings. Once the line is clear of debris, proceed to next step.
Page 15
Tighten using the Allen key. Push the indicator button holder into the lever handle top. 12. Proceed to installation of riser, pot filler & spray arm – page 15 www.enware.com.au Call 1300 369 273...
Page 16
5. Re-assemble the bracket, and fit the bracket onto the riser as high up as possible. This gives greater support and stability to the assembly. Gently tighten the two screws of the bracket onto riser using the 2.5mm Allen key provided. IMAGE 36 Call 1300 369 273 www.enware.com.au...
Page 17
IMAGE 41 IMAGE 42 Ensure the spigot has engaged into the socket properly. SEE IMAGE 39, 40 Ensure the grub screw has engaged into the groove properly. SEE IMAGE 41, 42 www.enware.com.au Call 1300 369 273...
Page 18
When not in use ensure all taps to the pre rinse assembly are turned off. The taps should not be left on when unattended as this maintains pressure to the hose and trigger spray assembly, which could result in water damage from flooding if in the unlikely event the hose or trigger spray were to malfunction. Call 1300 369 273 www.enware.com.au...
Page 19
Enware Product should be cleaned with a soft damp cloth using only mild liquid detergent or soap and water. Do not use cleaning agents containing a corrosive acid, scouring agent or solvent chemicals. Do not use cream cleaners, as they are abrasive.
Page 20
FS100 (585mm Standard), FS101 (385mm Spring Guard (Exterior Spring Guard Stainless Steel 316 Grade) Short) Sticker Label - Lever Tap Operation MIS620 For more information, go to our website - www.enware.com.au, enter product code in search keyword. Call 1300 369 273 www.enware.com.au...
Page 21
Always refer to instructions from Enware before disassembling any fitting. Spare part kits should be on hand before any service of the tap is undertaken. It is recommended that the trigger spray action be periodically serviced. The maintenance interval will depend on the frequency of use of the product, water quality and the general environment.
Page 22
Tighten screws on bracket or tighten come loose fixing nut to base O-rings have worn out Replace o-rings Grub screws have loosened Tighten grub screws. Use Loctite 577, Loxeal or similar sealant to fix grub screw in place Call 1300 369 273 www.enware.com.au...
Page 23
Form available on website www.enware.com.au. other conditions All notifications and accompanying forms must be sent to us marked for the attention of the Enware Australia Pty Limited, 9 Endeavour Road, Caringbah NSW 2229. We Except as provided or referred to in this document, we...
Need help?
Do you have a question about the FHS011 and is the answer not in the manual?
Questions and answers