Hitachi P 14 DSL Handling Instructions Manual page 11

Cordless planer
Table of Contents

Advertisement

3. Charging
<UC18YFSL>
When inserting a battery in the charger, the pilot lamp will
light up continuously in red.
When the battery becomes fully recharged, the pilot lamp
will blink in red (At 1-second intervals). (See Table 1-a)
● Pilot lamp indication
The indications of the pilot lamp will be as shown in
Table 1-a, according to the condition of the charger or
the rechargeable battery.
Before
charging
While
charging
Charging
Pilot lamp
complete
(red)
Overheat
standby
Charging
impossible
NOTE: When standby for cooling battery, UC18YFSL cools the overheated battery by cooling fan.
Before
charging
While
charging
Charge
indicator
lamp
(red /
blue /
Charging
green /
complete
purple)
Overheat
standby
Charging
impossible
NOTE: When standby for cooling battery, UC18YSL3 cools the overheated battery by cooling fan.
Indications of the pilot lamp
Lights for 0.5 seconds. Does not light
Blinks
for 0.5 seconds. (off for 0.5 seconds)
Lights continuously
Lights
Lights for 0.5 seconds. Does not light
Blinks
for 0.5 seconds. (off for 0.5 seconds)
Lights for 1 second. Does not light
Blinks
for 0.5 seconds. (off for 0.5 seconds)
Lights for 0.1 seconds. Does not light for
Flickers
0.1 seconds. (off for 0.1 seconds)
Indications of the charge indicator lamp
Lights for 0.5 seconds. Does not light for
Blinks
0.5 seconds. (off for 0.5 seconds)
(red)
Lights for 0.5 seconds. Does not light for
Blinks
1 second. (off for 1 second)
(blue)
Lights for 1 second. Does not light
Blinks
for 0.5 seconds. (off for 0.5 seconds)
(blue)
Lights
Lights continuously
(blue)
Lights continuously
Lights
(green)
(Continuous buzzer sound: about 6
seconds)
Lights for 0.3 seconds. Does not light for
Blinks
0.3 seconds. (off for 0.3 seconds)
(red)
Lights for 0.1 seconds. Does not light for
0.1 seconds. (off for 0.1 seconds)
Flickers
(purple)
(Intermittent buzzer sound: about
2 seconds)
<UC18YSL3>
When inserting a battery in the charger, the charge
indicator lamp will blink in blue.
When the battery becomes fully recharged, the charge
indicator lamp will light up in green. (See Table 1-b)
● Charge indicator lamp indication
The indications of the charge indicator lamp will be as
shown in Table 1-b, according to the condition of the
charger or the rechargeable battery.
Table 1-a
Table 1-b
Battery overheated.
Unable to charge.
(Charging will commence
when battery cools)
Malfunction in the battery
or the charger
Plugged into power source
Battery capacity at less than 50%
Battery capacity at less than 80%
Battery capacity at more than 80%
Battery overheated. Unable to charge.
(Charging will commence when battery
cools)
Malfunction in the battery or the
charger
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

P 18 dslP 18 dslh4z

Table of Contents